The DOI matches its Crossref record.
Antimyosin-labeled monocrystalline iron oxide allows detection of myocardial infarct: MR antibody imaging.
Abstract
The synthesis and in vivo antigen targeting of a novel iron oxide compound were studied. A monocrystalline iron oxide nanoparticle (MION) was synthesized that contains a small (mean diameter, 2.9 nm +/- 0.9) single crystal core, passes through capillary membranes, and exhibits superparamagnetism. The MION was attached to antimyosin Fab (R11D10) and used for immunospecific magnetic resonance (MR) imaging of cardiac infarcts One hour after intravenous administration of MION-R11D10 in rats (100 mumol/kg), a marked decrease in the signal intensity of infarcted myocardium was observed. Immunohistochemical correlation confirmed the specific binding of the immunoconjugate to infarcted, but not to normal, myocardium. No decrease in cardiac signal intensity was observed when unconjugated MION was administered intravenously. The results indicate the feasibility of immunospecific MR imaging in living organisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Multifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Self-citationSuperparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Metadata
- Authors
- Weissleder, R., Lee, A. S., Khaw, B. A., Shen, T., & Brady, T. J.
- Venue
- Radiology
- Published
- 1992-02
- Volume
- 182
- Issue
- 2
- Pages
- 381-385
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2151354541
- Cited by
- 186
- References
- 0
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antimyosin-labeled monocrystalline iron oxide allows detection of myocardial infarct: MR antibody imaging. https://app.cochat.ai/papers/10.1148/radiology.182.2.1732953
- The paper
- Weissleder, R., Lee, A. S., Khaw, B. A., Shen, T., & Brady, T. J. (1992). Antimyosin-labeled monocrystalline iron oxide allows detection of myocardial infarct: MR antibody imaging. Radiology. https://doi.org/10.1148/radiology.182.2.1732953
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.