Nephrotoxicity of high-osmolality versus low-osmolality contrast media: randomized clinical trial.
The DOI matches its Crossref record.
Abstract
The comparative frequency of and risk factors for nephrotoxicity with low-osmolality contrast medium (LOM) versus high-osmolality contrast medium (HOM) were investigated. A randomized, double-blind clinical trial was conducted in patients undergoing diagnostic angiocardiography (n = 430) or contrast material-enhanced body computed tomography (CT) (n = 499). Nephrotoxicity was defined as an increase in serum creatinine level that was greater than both 33% and 0.4 mg/dL (40 mumols/L) above the baseline level within 48 hours after the radiologic procedure. The frequency of nephrotoxicity was similar in patients who received LOM versus those who received HOM: 13 of 479 (2.7%) versus 13 of 450 (2.9%), respectively (P = .87), overall; 4.4% versus 4.0% in angiocardiography patients (P = .84); and 1.2% versus 2.0% in body CT patients (P = .35). Factors associated (P less than .05) with increased risk of nephrotoxicity were insulin-dependent diabetes, baseline serum creatinine level greater than 1.5 mg/dL (130 mumols/L), concurrent use of furosemide, and angiocardiographic examination. Patients who have preexisting renal insufficiency may be at higher risk for nephrotoxicity with HOM than with LOM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contrast-Induced Acute Kidney Injury
McCullough, P. A., Choi, J. P., Feghali, G. A., Schussler, J. M., Stoler, R. M., Vallabahn, R. C., & Mehta, A. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.05.099 · Cited by 1,067
Nephrotoxicity of ionic and nonionic contrast media in 1196 patients: A randomized trial
Rudnick, M. R., Goldfarb, S., Wexler, L., Ludbrook, P. A., Murphy, M. J., Halpern, E. F., Hill, J. A., Winniford, M., Cohen, M. B., VanFossen, D. B., et al. (1995) · Kidney International · doi:10.1038/ki.1995.32 · Cited by 923
Contrast-Induced Acute Kidney Injury
McCullough, P. A. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.12.035 · Cited by 822
Contrast-media-induced nephrotoxicity: a consensus report
Morcos, S. K., Thomsen, H. S., & Webb, J. A. W. (1999) · European Radiology · doi:10.1007/s003300050894 · Cited by 527
Contrast-Induced Nephropathy: A Clinical and Evidence-Based Approach
Tepel, M., Aspelin, P., & Lameire, N. (2006) · Circulation · doi:10.1161/circulationaha.105.595090 · Cited by 506
Risk Prediction of Contrast-Induced Nephropathy
McCullough, P. A., Adam, A., Becker, C. R., Davidson, C., Lameire, N., Stacul, F., & Tumlin, J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.022 · Cited by 457
Kay, J., Chow, W. H., Chan, T. M., Lo, S. K., Kwok, O. H., Yip, A., Fan, K., Lee, C. H., & Lam, W. F. (2003) · JAMA · doi:10.1001/jama.289.5.553 · Cited by 434
Prophylaxis Strategies for Contrast-Induced Nephropathy
Pannu, N., Wiebe, N., Tonelli, M., & Alberta Kidney Disease Network, F. T. (2006) · JAMA · doi:10.1001/jama.295.23.2765 · Cited by 410
Nephropathy induced by contrast media: pathogenesis, risk factors and preventive strategies
Goldenberg, I. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.1040847 · Cited by 375
Side Effects of Radiographic Contrast Media: Pathogenesis, Risk Factors, and Prevention
Andreucci, M., Solomon, R., & Tasanarong, A. (2014) · BioMed Research International · doi:10.1155/2014/741018 · Cited by 354
Mohamadnejad, M. (2007) · World Journal of Gastroenterology · doi:10.3748/wjg.v13.i24.3359 · Cited by 179
Dussol, B., Morange, S., Loundoun, A., Auquier, P., & Berland, Y. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl133 · Cited by 159
“Several studies have demonstrated a significant correlation between CN and contrast medium volume [5,37,38], although in other studies no such relationship was found [34–35,39].”
Result
Metadata
- Authors
- Moore, R. D., Steinberg, E. P., Powe, N. R., Brinker, J. A., Fishman, E. K., Graziano, S., & Gopalan, R.
- Venue
- Radiology
- Published
- 1992-03
- Volume
- 182
- Issue
- 3
- Pages
- 649-655
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2129892232
- Cited by
- 204
- References
- 0
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.