The DOI matches its Crossref record.
Flow dynamics of cerebrospinal fluid: assessment with phase-contrast velocity MR imaging performed with retrospective cardiac gating.
Abstract
To visualize the flow of cerebrospinal fluid (CSF) throughout the ventricles and subarachnoid space, measure mean and maximum CSF velocities, and quantitate CSF flow through the aqueduct of Sylvius, magnetic resonance (MR) imaging was performed with a sagittal technique that is flow-sensitive in the craniocaudal direction (along the readout axis) and a high-resolution axial technique sensitive to through-plane flow in three healthy subjects and 19 patients with known or suspected disorders of the CSF circulation. In both techniques, retrospective cardiac gating was used to cover the complete cardiac cycle. The sagittal technique was superior in overall assessment of CSF flow dynamics, including the motion of adjacent brain parenchyma. The high-resolution axial technique provided an accurate measurement of the rate of CSF flow through the aqueduct; only this technique provided sufficient accuracy to enable distinction between normal and hyperdynamic CSF flow. It is concluded that assessment of CSF flow dynamics is a useful adjunct to routine MR imaging in communicating and obstructive hydrocephalus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new look at cerebrospinal fluid circulation
Brinker, T., Stopa, E., Morrison, J., & Klinge, P. (2014) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-11-10 · Cited by 819
Oldfield, E. H., Muraszko, K., Shawker, T. H., & Patronas, N. J. (1994) · Journal of Neurosurgery · doi:10.3171/jns.1994.80.1.0003 · Cited by 763
Mechanisms of fluid movement into, through and out of the brain: evaluation of the evidence
Hladky, S. B., & Barrand, M. A. (2014) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-11-26 · Cited by 633
Retrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
Wagshul, M. E., Eide, P. K., & Madsen, J. R. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-5 · Cited by 473
Metadata
- Authors
- Nitz, W. R., Bradley, W. G., Watanabe, A. S., Lee, R. R., Burgoyne, B., O'Sullivan, R. M., & Herbst, M. D.
- Venue
- Radiology
- Published
- 1992-05
- Volume
- 183
- Issue
- 2
- Pages
- 395-405
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2047913307
- Cited by
- 273
- References
- 0
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow dynamics of cerebrospinal fluid: assessment with phase-contrast velocity MR imaging performed with retrospective cardiac gating. https://app.cochat.ai/papers/10.1148/radiology.183.2.1561340
- The paper
- Nitz, W. R., Bradley, W. G., Watanabe, A. S., Lee, R. R., Burgoyne, B., O'Sullivan, R. M., & Herbst, M. D. (1992). Flow dynamics of cerebrospinal fluid: assessment with phase-contrast velocity MR imaging performed with retrospective cardiac gating. Radiology. https://doi.org/10.1148/radiology.183.2.1561340
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.