Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 250

The DOI matches its Crossref record.

Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.

Remy-Jardin, M, Remy, J, Giraud, F, Marquette, C H · 1993 · Radiology

Abstract

Spiral volumetric computed tomography (CT) with single breath-hold technique was compared with conventional sequential CT in 39 patients. The spiral CT protocol consisted of a 10 mm/sec table feed during a 24-second breath hold at 145 mA, with reconstruction of images at 10-mm intervals; one (n = 21) or two (n = 18) sequences were necessary to screen the complete lung. Conventional CT was performed with a 1-second scan time, 145 mA, and contiguous 10-mm-thick sections. In the 39 patients studied with each technique, no lung nodule was detected in three, two had a single nodule, and 29 had multiple nodules. Two patients with normal findings at chest radiography and three with a solitary pulmonary nodule at conventional CT had multiple nodules at spiral CT. Mean number of nodules per patient was significantly higher with spiral versus conventional CT (18 +/- 4.5 vs 12.6 +/- 3.2 [mean +/- standard error of the mean], P = .01) as were the number of nodules less than 5 mm in diameter per patient (12.7 +/- 3.7 vs 8.4 +/- 2.3, P < .05) and 5-10 mm in diameter (2.9 +/- 0.9 vs 2.4 +/- 0.8, P < .05). Respiratory motion artifacts were never observed with spiral CT although they were present on four conventional CT scans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.187.2.8475300

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 250

Metadata

Authors
Remy-Jardin, M., Remy, J., Giraud, F., & Marquette, C. H.
Venue
Radiology
Published
1993-05
Volume
187
Issue
2
Pages
513-520
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1970515849
Cited by
250
References
0
FWCI
13.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. https://app.cochat.ai/papers/10.1148/radiology.187.2.8475300
The paper
Remy-Jardin, M., Remy, J., Giraud, F., & Marquette, C. H. (1993). Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology. https://doi.org/10.1148/radiology.187.2.8475300

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.