The DOI matches its Crossref record.
Evaluation of breast masses and axillary lymph nodes with [F-18] 2-deoxy-2-fluoro-D-glucose PET.
Abstract
Twenty-eight patients with a total of 35 suspect breast masses underwent positron emission tomography (PET) with [fluorine-18] 2-deoxy-2-fluoro-D-glucose (FDG) in order to study the utility of this technique in the evaluation of breast cancer. FDG PET allowed discrimination between eight benign and 27 malignant breast masses, with a sensitivity of 96% and specificity of 100%. Among the malignancies, there was a significant correlation between normalized FDG uptake and nuclear grade (P = .006). In addition, the results of PET imaging were compared with results of axillary node dissection in 20 cases of breast cancer. PET allowed correct categorization of 10 of 10 axillae as negative (specificity = 100%). PET results were equivocal in one axilla and positive in the remaining nine of 10 axillae with positive dissection results (sensitivity = 90%). The authors conclude that FDG PET may give useful information on breast masses and axillary node status prior to surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2001) · PubMed · Cited by 943
Schelling, M., Avril, N., Nährig, J., Kuhn, W., Römer, W., Sattler, D., Werner, M., Dose, J., Jänicke, F., Graeff, H., et al. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.8.1689 · Cited by 522
Treatment of early-stage breast cancer
Hurd, T. C., Edge, S. B., Kahlenberg, M. S., Stomper, P. C., Proulx, G. M., Schwartz, G., Khatri, V., & Winston, J. S. (1999) · Current Problems in Cancer · doi:10.1016/s0147-0272(99)90004-1 · Cited by 477
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
FDG PET Evaluation of Mucinous Neoplasms: Correlation of FDG Uptake with Histopathologic Features
Berger, K. L., Nicholson, S. A., Dehdashti, F., & Siegel, B. A. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1741005 · Cited by 351
Metadata
- Authors
- Adler, L. P., Crowe, J. P., al-Kaisi, N. K., & Sunshine, J. L.
- Venue
- Radiology
- Published
- 1993-06
- Volume
- 187
- Issue
- 3
- Pages
- 743-750
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2093928399
- Cited by
- 372
- References
- 0
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of breast masses and axillary lymph nodes with [F-18] 2-deoxy-2-fluoro-D-glucose PET. https://app.cochat.ai/papers/10.1148/radiology.187.3.8497624
- The paper
- Adler, L. P., Crowe, J. P., al-Kaisi, N. K., & Sunshine, J. L. (1993). Evaluation of breast masses and axillary lymph nodes with [F-18] 2-deoxy-2-fluoro-D-glucose PET. Radiology. https://doi.org/10.1148/radiology.187.3.8497624
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.