The DOI matches its Crossref record.
Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data.
Abstract
Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the anatomic short- and horizontal long-axis planes with cine MR imaging. LV volumes were measured with various geometric models, and ejection fractions were calculated. In both groups, the values of LV stroke volume obtained with a modified Simpson rule and biplane ellipsoid models correlated well to the analysis of the three-dimensional data set of cine MR images. There were no significant differences for the calculated ejection fraction between values obtained with the modified Simpson rule or the biplane ellipsoid model versus the three-dimensional data set. A high inter-observer reproducibility of cine MR measurements with the two former models was found. Therefore, modified Simpson rule and biplane ellipsoid models, with their shorter acquisition and processing times, may increase the clinical utility of cine MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hudsmith†, L., Petersen†, S., Francis, J., Robson, M., & Neubauer, S. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500295516 · Cited by 627
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Sandstede, J., Lipke, C., Beer, M., Hofmann, S., Pabst, T., Kenn, W., Neubauer, S., & Hahn, D. (2000) · European Radiology · doi:10.1007/s003300050072 · Cited by 274
Chuang, M. L., Hibberd, M. G., Salton, C. J., Beaudin, R. A., Riley, M. F., Parker, R. A., Douglas, P. S., & Manning, W. J. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00551-3 · Cited by 272
Haufe, S., Utz, W., Engeli, S., Kast, P., Böhnke, J., Pofahl, M., Traber, J., Haas, V., Hermsdorf, M., Mähler, A., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.178616 · Cited by 73
Metadata
- Authors
- Dulce, M. C., Mostbeck, G. H., Friese, K. K., Caputo, G. R., & Higgins, C. B.
- Venue
- Radiology
- Published
- 1993-08
- Volume
- 188
- Issue
- 2
- Pages
- 371-376
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2014903099
- Cited by
- 195
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data. https://app.cochat.ai/papers/10.1148/radiology.188.2.8327680
- The paper
- Dulce, M. C., Mostbeck, G. H., Friese, K. K., Caputo, G. R., & Higgins, C. B. (1993). Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data. Radiology. https://doi.org/10.1148/radiology.188.2.8327680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.