The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Human brain: Proton diffusion MR spectroscopy
Abstract
Diffusion of brain metabolites was measured in 10 healthy volunteers by using localized proton diffusion magnetic resonance (MR) spectroscopy. Measurements were conducted with a clinical MR imager by using a stimulated-echo pulse sequence (3,000/60 [repetition time msec/echo time msec], 200-msec mixing time) with additional outside-volume suppression. Motion artifacts due to macroscopic brain movements were compensated by means of peripheral cardiac gating and separate collection of individual spectroscopic acquisitions into a two-dimensional data matrix. Phase errors due to macroscopic motion were subsequently corrected in individual data traces prior to spectral averaging. Mean (+/- 1 standard deviation) apparent diffusion coefficients of choline-containing compounds ([0.13 +/- 0.03] x 10(-3) mm2/sec), creatine and phosphocreatine ([0.15 +/- 0.03] x 10(-3) mm2/sec), and N-acetyl aspartate ([0.18 +/- 0.02] x 10(-3) mm2/sec) were substantially smaller than that of water and were consistent with recently published data obtained in anesthetized and paralyzed animals. Adequate diffusion sensitivity for metabolites in the human brain can be obtained with clinical whole-body imagers despite macroscopic head and brain movements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diffusion MRI has also been used to investigate the diffusion of nonwater molecules in the human brain, notably metabolites and neurotransmitters (Posse et al., 1993).”
From 40 Years of diffusion MRI in the brain: From history to emerging frontiers (2026) · cites this paper as Posse et al., 1993
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,239
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Bihan, D. L., Breton, E., Lallemand, D. P., Aubin, M., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,174
Self-diffusion in normal and heavy water in the range 1-45.deg.
Mills, R. (1973) · The Journal of Physical Chemistry · doi:10.1021/j100624a025 · Cited by 1,726
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J. R., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J. S., & Norman, D. M. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,132
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hänicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Moseley, M. E., Kucharczyk, J. R., Mintorovitch, J., Cohen, Y., Kurhanewicz, J. V., Derugin, N., Asgari, H. S., & Norman, D. M. (2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Localized proton spectroscopy using stimulated echoes
Frahm, J., Merboldt, K., & Hänicke, W. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90154-5 · Cited by 837
Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910110105 · Cited by 522
Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo.
Chenevert, T. L., Brunberg, J. A., & Pipe, J. G. (1990) · Radiology · doi:10.1148/radiology.177.2.2217776 · Cited by 503
Molecular diffusion nuclear magnetic resonance imaging.
Bihan, D. L. (1991) · PubMed · Cited by 438
Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging.
Feinberg, D. A., & Mark, A. S. (1987) · Radiology · doi:10.1148/radiology.163.3.3575734 · Cited by 378
Brain parenchyma motion: measurement with cine echo-planar MR imaging.
Poncelet, B. P., Wedeen, V. J., Weisskoff, R. M., & Cohen, M. S. (1992) · Radiology · doi:10.1148/radiology.185.3.1438740 · Cited by 285
Brain motion: measurement with phase-contrast MR imaging.
Enzmann, D. R., & Pelc, N. J. (1992) · Radiology · doi:10.1148/radiology.185.3.1438741 · Cited by 275
van Zijl, P. C. M., MOONEN, C. T. W., Faustino, P., Pekar, J. J., Kaplan, O., & Cohen, J. S. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.8.3228 · Cited by 220
Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopy
MOONEN, C. T. W., von Kienlin, M., van Zijl, P. C. M., Cohen, J. S., Gillen, J., Daly, P. F., & Wolf, G. L. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020506 · Cited by 215
Volume-selective multipulse spin-echo spectroscopy
Kimmich, R., & Hoepfel, D. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90304-0 · Cited by 192
Granot, J. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90142-3 · Cited by 148
Highly Effective Water Suppression for in vivo proton NMR Spectroscopy (DRYSTEAM)
MOONEN, C. T. W., & van Zijl, P. C. M. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90106-j · Cited by 140
Effects of susceptibility variations on NMR measurements of diffusion
Zhong, J., Kennan, R. P., & Gore, J. C. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90217-h · Cited by 125
In vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnet
Barfuss, H., Fischer, H., Hentschel, D., Ladebeck, R., Oppelt, A., Wittig, R., Duerr, W., & Oppelt, R. (1990) · NMR in Biomedicine · doi:10.1002/nbm.1940030106 · Cited by 119
Short Echo Time Proton MR Spectroscopic Imaging
Posse, S., Schuknecht, B., Smith, M. E., van Zijl, P. C. M., HERSCHKOWITZ, N. N., & MOONEN, C. T. W. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199301000-00001 · Cited by 97
Self-citationMR Imaging of Anisotropically Restricted Diffusion in the Brain of Neonates and Infants
Rutherford, M., Cowan, F. M., Manzur, A. Y., Dubowitz, L. M. S., Pennock, J. M., Hajnal, J. V., YOUNG, I. R., & Bydder, G. M. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199103000-00002 · Cited by 87
Merboldt, K., Hörstermann, D., Hänicke, W., Bruhn, H., & Frahm, J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290123 · Cited by 69
Motion Artifact Compensation in 1H Spectroscopic Imaging by Signal Tracking
Posse, S., Cuénod, C. A., & Bihan, D. L. (1993) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1993.1088 · Cited by 33
Self-citationThe human brain: localized H-1 MR spectroscopy at 1.0 T.
Sauter, R., Loeffler, W., Bruhn, H., & Frahm, J. (1990) · Radiology · doi:10.1148/radiology.176.1.2353095 · Cited by 26
Klammler, F., & Kimmich, R. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/1/007 · Cited by 19
Motion rephasing in gradient-localized spectroscopy
Gyngell, M. L., Frahm, J., Merboldt, K. D., Hänicke, W., & Bruhn, H. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90020-0 · Cited by 11
4780674 Process for imaging by nuclear magnetic resonance
Breton, E., & Bihan, D. L. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90230-y · Cited by 1
Cited by
Sorted by citations
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Punwani, S., Ordidge, R. J., Cooper, C. E., Amess, P., & Clemence, M. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6 · Cited by 74
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. J. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 542
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 240
Metadata
- Authors
- Posse, S., Cuenod, C. A., & Le Bihan, D.
- Affiliations
- National Institutes of Health (US)
- ORCID
- Posse, S
- Venue
- Radiology
- Published
- 1993-09
- Volume
- 188
- Issue
- 3
- Pages
- 719-725
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2055971737
- Cited by
- 122
- References
- 29
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 5 · 2022: 3 · 2021: 2 · 2020: 7 · 2019: 3 · 2018: 6 · 2017: 5 · 2016: 5 · 2015: 6 · 2014: 6 · 2013: 1 · 2012: 3
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- apparent diffusion coefficient, brain metabolites, choline-containing compounds, creatine, phosphocreatine, N-acetylaspartate, motion correction, cardiac gating, phase correction
- MeSH terms
- Adult, Aspartic Acid, Brain Chemistry, Choline, Creatine, Female, Humans, Male, Magnetic Resonance Spectroscopy, Phosphocreatine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review