The DOI matches its Crossref record.
Imaging of the skin with 20-MHz US.
Abstract
PURPOSE: The authors clinically evaluated a new high-frequency ultrasound (US) scanner to determine the value of US for dermatologic applications. MATERIALS AND METHODS: A 20-MHz US scanner was used to visualize normal skin at eight sites in 10 healthy volunteers and to evaluate 200 skin lesions (45 malignant, 155 benign). RESULTS: In normal skin, the dermis was markedly echogenic and sharply demarcated from hypoechoic subcutaneous fat. The epidermis was not resolved except on the palm and sole. Only three superficial lesions were not identified with US; evaluation of another three was limited by shadowing. Thickness of the lesions visualized was 0.2-26.0 mm (mean, 1.9 mm +/- 2.6). Most lesions (77%) were hypoechoic, 9% were anechoic, 12% had mixed echogenicity, and 2% were isoechoic or hyperechoic. CONCLUSION: The diagnostic role of high-frequency US appears limited. It did not help differentiate benign from malignant lesions, but it did enable accurate delineation of deep margins of lesions and allowed noninvasive measurement of thickness. These features may help in the preoperative evaluation of skin tumors and in monitoring the response to therapy for certain inflammatory conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Terahertz Pulse Imaging of ex vivo Basal Cell Carcinoma
Woodward, R. M., Wallace, V. P., Pye, R. J., Cole, B. E., Arnone, D. D., Linfield, E. H., & Pepper, M. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12013.x · Cited by 434
Clinical usefulness of variable-frequency ultrasound in localized lesions of the skin
Wortsman, X., & Wortsman, J. (2010) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2009.06.016 · Cited by 302
An introduction to medical imaging with coherent terahertz frequency radiation
Fitzgerald, A. J., Berry, E., Zinovev, N. N., Walker, G. C., Smith, M. A., & Chamberlain, J. M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/7/201 · Cited by 255
Laurent, A., Mistretta, F., Bottigioli, D., Dahel, K., Goujon, C., Nicolas, J. F., Hennino, A., & Laurent, P. E. (2007) · Vaccine · doi:10.1016/j.vaccine.2007.05.046 · Cited by 235
Metadata
- Authors
- Fornage, B. D., McGavran, M. H., Duvic, M., & Waldron, C. A.
- Venue
- Radiology
- Published
- 1993-10
- Volume
- 189
- Issue
- 1
- Pages
- 69-76
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2080628117
- Cited by
- 176
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging of the skin with 20-MHz US. https://app.cochat.ai/papers/10.1148/radiology.189.1.8372222
- The paper
- Fornage, B. D., McGavran, M. H., Duvic, M., & Waldron, C. A. (1993). Imaging of the skin with 20-MHz US. Radiology. https://doi.org/10.1148/radiology.189.1.8372222
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.