Gadolinium-enhanced MR aortography.
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate the potential for preferential arterial enhancement at magnetic resonance (MR) aortography with an intravenous infusion of paramagnetic contrast material. MATERIALS AND METHODS: Gadolinium chelates were administered intravenously (0.2 mmol/kg) during three-dimensional MR imaging (1.5 T) in 125 patients (77 male and 48 female patients, aged 4-86 years [mean, 66 years]) with suspected aorta or aortic branch vessel disease. RESULTS: Infusion for the duration of the MR acquisition resulted in significant preferential arterial enhancement without the confounding effects of excessive venous or background-tissue enhancement (P < 10(-5)). Angiographic or surgical correlation in 48 patients revealed an 88% sensitivity and a 97% specificity for detection of stenoses or occlusions and a 100% sensitivity and a 100% specificity for detection of aortic or iliac artery aneurysms. CONCLUSION: Preferential arterial enhancement is possible at MR aortography with an intravenous infusion of paramagnetic contrast material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
Time‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
Ruehm, S. G., Corot, C., Vogt, P., Kolb, S., & Debatin, J. F. (2001) · Circulation · doi:10.1161/01.cir.103.3.415 · Cited by 599
Burrel, M., Llovet, J. M., Ayuso, C., Iglesias, C., Sala, M., Miquel, R., Caralt, T., Ayuso, J. R., Solé, M., Sanchez, M., et al. (2003) · Hepatology · doi:10.1002/hep.1840380430 · Cited by 451
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Self-citationMiyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Nephrotoxicity of high‐dose gadolinium compared with iodinated contrast
Prince, M. R., Arnoldus, C., & Frisoli, J. K. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060129 · Cited by 398
Self-citationMR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography.
Ho, K. Y., Leiner, T., de Haan, M. W., Kessels, A. G., Kitslaar, P. J., & van Engelshoven, J. M. (1998) · Radiology · doi:10.1148/radiology.206.3.9494486 · Cited by 301
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“By making some assumptions about the physiology of the patient and that the contrast agent mixes evenly with the blood pool during the first pass stage, it is possible to estimate how mixing with the blood pool affects concentration of the contrast medium in the arterial system during the first pass for a given inject…”
Li, W., Tutton, S., Vu, A. T., Pierchala, L., Li, B. S. Y., Lewis, J. M., Prasad, P. V., & Edelman, R. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20235 · Cited by 232
LaConte, L., Nitin, N., & Bao, G. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00893-x · Cited by 229
Magnetic Resonance Angiography for the Diagnosis of Renal Artery Stenosis: A Meta-analysis
Tan, K. T., van Beek, E. J. R., Brown, P. W. G., van Delden, O. M., Tijssen, J., & Ramsay, L. E. (2002) · Clinical Radiology · doi:10.1053/crad.2002.0941 · Cited by 202
Perspectives with cryogenic RF probes in biomedical MRI
Darrasse, L. (2003) · Biochimie · doi:10.1016/j.biochi.2003.09.016 · Cited by 201
High-Resolution MR Venography at 3.0 Tesla
Reichenbach, J. R., Barth, M., Haacke, E. M., Klarhöfer, M., Kaiser, W. A., & Moser, E. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200011000-00023 · Cited by 199
A review of responsive MRI contrast agents: 2005–2014
Hingorani, D. V., Bernstein, A. S., & Pagel, M. D. (2015) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1629 · Cited by 199
“For example, MRI contrast agents are routinely administered to patients and animal models to track vascular flow for large arteries and veins using MRI angiography (14).”
BackgroundRuehm, S. G., Hany, T. F., Pfammatter, T., Schneider, E., Ladd, M., & Debatin, J. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1741127 · Cited by 177
Bjørnerud, A., & Johansson, L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.904 · Cited by 173
Non‐contrast enhanced MR angiography: Physical principles
Wheaton, A. J., & Miyazaki, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23641 · Cited by 168
Wang, Y., Johnston, D. L., Breen, J. F., Iii, J. H., Jack, C. R., Julsrud, P. R., Kiely, M. J., King, B. F., Riederer, S. L., & Ehman, R. L. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360408 · Cited by 162
“To optimize the MR signal at the bolus peak in our experiments, we chose 45” as the flip angle, which is consistent with the literature (3).”
BackgroundMethodInfluentialPharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent
Misselwitz, B., Schmitt-Willich, H., Ebert, W., Frenzel, T., & Weinmann, H.-J. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668094 · Cited by 158
“/Magnetic Resonance Materials' in Physics, Biology and Medichw 12 (2001) 128-134 129”
BackgroundInfluentialSchnorr, J., Wagner, S., Abramjuk, C., Wojner, I., Schink, T., Kroencke, T. J., Schellenberger, E., Hamm, B., Pilgrimm, H., & Taupitz, M. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000133944.30119.cc · Cited by 54
Klein, C., Schalla, S., Schnackenburg, B., Bornstedt, A., Hoffmann, V., Fleck, E., & Nagel, E. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10317 · Cited by 29
Metadata
- Authors
- Prince, M. R.
- Venue
- Radiology
- Published
- 1994-04
- Volume
- 191
- Issue
- 1
- Pages
- 155-164
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2111350768
- Cited by
- 884
- References
- 0
- FWCI
- 40.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.