The DOI matches its Crossref record.
Computer-aided mammographic screening for spiculated lesions.
Abstract
PURPOSE: To study the use of a computer vision method as a second reader for the detection of spiculated lesions on screening mammograms. MATERIALS AND METHODS: An algorithmic computer process for the detection of spiculated lesions on digitized screen-film mammograms was applied to 85 four-view clinical cases: 36 cases with cancer proved by means of biopsy and 49 cases with negative findings at examination and follow-up. The computer detections were printed as film with added outlines that indicated the suspected cancers. Four radiologists screened the 85 cases twice, once without and once with the computer reports as ancillary films. RESULTS: The algorithm alone achieved 100% sensitivity, with a specificity of 82%. The computer reports increased the average radiologist sensitivity by 9.7% (P = .005), moving from 80.6% to 90.3%, with no decrease in average specificity. CONCLUSION: The study demonstrated that computer analysis of mammograms can provide a substantial and statistically significant increase in radiologist screening efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Birdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428
Sahiner, B., Chan, H.-P., Petrick, N., Wei, D., Helvie, M. A., Adler, D. D., & Goodsitt, M. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538937 · Cited by 420
A review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Metadata
- Authors
- Kegelmeyer, W. P., Pruneda, J. M., Bourland, P. D., Hillis, A., Riggs, M. W., & Nipper, M. L.
- Venue
- Radiology
- Published
- 1994-05
- Volume
- 191
- Issue
- 2
- Pages
- 331-337
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2014408515
- Cited by
- 278
- References
- 0
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-aided mammographic screening for spiculated lesions. https://app.cochat.ai/papers/10.1148/radiology.191.2.8153302
- The paper
- Kegelmeyer, W. P., Pruneda, J. M., Bourland, P. D., Hillis, A., Riggs, M. W., & Nipper, M. L. (1994). Computer-aided mammographic screening for spiculated lesions. Radiology. https://doi.org/10.1148/radiology.191.2.8153302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.