The DOI matches its Crossref record.
Initial clinical experience with dextran-coated superparamagnetic iron oxide for detection of lymph node metastases in patients with head and neck cancer.
Abstract
PURPOSE: To investigate the efficacy of magnetic resonance (MR) imaging with dextran-coated superparamagnetic iron oxide in the differentiation of metastatic and benign nodes in patients with head and neck cancer. MATERIALS AND METHODS: MR imaging was performed before and after intravenous administration of iron oxide in 12 patients. Ninety-one pathologically proved nodes were visually analyzed, and 66 lymph nodes were quantitatively analyzed by measuring signal intensity in visually selected regions of interest. RESULTS: Forty of 42 histologically proved metastatic nodes and 41 of 49 benign nodes were detected, yielding 95% sensitivity and 84% specificity. The signal intensity ratio of benign nodes was substantially lower than that of metastatic nodes, indicating better differentiation of metastatic and benign nodes. Furthermore, 13 of 14 normal-sized nodes were detected. CONCLUSION: MR imaging with iron oxide can enable specific differentiation of metastatic and benign nodes in patients with head and neck cancer. This agent may potentially enhance the detection of metastatic lymph nodes and deserves further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Heesakkers, R. A., Hövels, A. M., Jager, G. J., van den Bosch, H. C., Witjes, J. A., Raat, H. P., Severens, J. L., Adang, E. M., van der Kaa, C. H., Fütterer, J. J., et al. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70203-1 · Cited by 307
Magnetite nanoparticles with tunable gold or silver shell
Mandal, M., Kundu, S., Ghosh, S. K., Panigrahi, S., Sau, T. K., Yusuf, S. M., & Pal, T. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.01.013 · Cited by 287
Metadata
- Authors
- Anzai, Y., Blackwell, K. E., Hirschowitz, S. L., Rogers, J. W., Sato, Y., Yuh, W. T., Runge, V. M., Morris, M. R., McLachlan, S. J., & Lufkin, R. B.
- Venue
- Radiology
- Published
- 1994-09
- Volume
- 192
- Issue
- 3
- Pages
- 709-715
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2073288904
- Cited by
- 220
- References
- 0
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial clinical experience with dextran-coated superparamagnetic iron oxide for detection of lymph node metastases in patients with head and neck cancer. https://app.cochat.ai/papers/10.1148/radiology.192.3.7520182
- The paper
- Anzai, Y., Blackwell, K. E., Hirschowitz, S. L., Rogers, J. W., Sato, Y., Yuh, W. T., Runge, V. M., Morris, M. R., McLachlan, S. J., & Lufkin, R. B. (1994). Initial clinical experience with dextran-coated superparamagnetic iron oxide for detection of lymph node metastases in patients with head and neck cancer. Radiology. https://doi.org/10.1148/radiology.192.3.7520182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.