The DOI matches its Crossref record.
Power versus conventional color Doppler sonography: comparison in the depiction of normal intrarenal vasculature.
Abstract
PURPOSE: To compare power Doppler sonography with color Doppler sonography in the depiction of normal intrarenal vasculature. MATERIALS AND METHODS: Twenty kidneys in 10 healthy, nonobese subjects were studied with color Doppler and power Doppler sonography at 3.5 MHz and a pulse repetition frequency of 800 Hz. The color gain was increased until "noise" first became perceptible. To standardize comparison, an ultrasound phantom was scanned with both techniques at the mean depth of each kidney. RESULTS: Power Doppler sonography demonstrated a diffuse "blush" of either the entire or almost the entire cortex in 18 of 20 kidneys and in approximately half the cortex of the two other kidneys. Color Doppler sonography did not depict a cortical blush in any kidney. In addition, subjective comparison showed that power Doppler sonography demonstrated the intrarenal vasculature better than color Doppler sonography in all kidneys. CONCLUSION: Power Doppler sonography was superior to color Doppler sonography in the demonstration of normal intrarenal vasculature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Updated Society for Vascular Surgery guidelines for management of extracranial carotid disease
Ricotta, J. J., AbuRahma, A., Ascher, E., Eskandari, M., Faries, P., & Lal, B. K. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.07.031 · Cited by 611
Colour Doppler energy (power) mode ultrasound
Macsweeney, J. E., Cosgrove, D. O., & Arenson, J. (1996) · Clinical Radiology · doi:10.1016/s0009-9260(96)80155-3 · Cited by 63
Hernandez‐Andrade, E., Jansson, T., Ley, D., Bellander, M., Persson, M., Lingman, G., & Maršál, K. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1002 · Cited by 58
Collins, S. L., Stevenson, G. N., Noble, J. A., Impey, L., & Welsh, A. W. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10122 · Cited by 52
Quantification of power Doppler and the index 'fractional moving blood volume' (FMBV)
Welsh, A. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1037 · Cited by 44
Metadata
- Authors
- Bude, R. O., Rubin, J. M., & Adler, R. S.
- Venue
- Radiology
- Published
- 1994-09
- Volume
- 192
- Issue
- 3
- Pages
- 777-780
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2029136566
- Cited by
- 250
- References
- 0
- FWCI
- 13.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Power versus conventional color Doppler sonography: comparison in the depiction of normal intrarenal vasculature. https://app.cochat.ai/papers/10.1148/radiology.192.3.8058946
- The paper
- Bude, R. O., Rubin, J. M., & Adler, R. S. (1994). Power versus conventional color Doppler sonography: comparison in the depiction of normal intrarenal vasculature. Radiology. https://doi.org/10.1148/radiology.192.3.8058946
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.