Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

Hemochromatosis: diagnosis and quantification of liver iron with gradient-echo MR imaging.

Gandon, Y, Guyader, D, Heautot, J F, Reda, M I, Yaouanq, J, Buhé, T, Brissot, P, Carsin, M, Deugnier, Y·1994·Radiology

Abstract

PURPOSE: To assess the role of magnetic resonance (MR) imaging in detection and quantification of liver iron overload. MATERIALS AND METHODS: MR imaging at 0.5 T was prospectively performed on 77 patients (67 with liver iron overload and 10 without) who underwent a liver biopsy with biochemical determination of the liver iron concentration (LIC) (normal, < 36 mumol per gram of liver tissue [dry weight]). Ratios of signal intensities and liver T2 relaxation time were calculated from images obtained with spin-echo and breath-hold gradient-echo (GRE) sequences. RESULTS: Liver-to-tissue signal intensity ratios were better correlated with LIC than T2 relaxation time. Long-echo-time GRE sequences were the most sensitive for detection of slight overload. Thus, high sensitivity (94%) and specificity (90%) were obtained with a liver-to-fat ratio threshold of 1. The quantification of iron with MR imaging was accurate when the LIC was 80-300 mumol/g. For heavy overload, above 300 mumol/g, quantification was impossible owing to complete signal loss. Pancreatic and splenic signal intensity were unchanged in most cases. CONCLUSION: This method, which can be improved by using more sensitive sequences with a high-field-strength system, should be competitive with biopsy for the diagnosis of substantial liver iron overload.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.193.2.7972774

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Gandon, Y., Guyader, D., Heautot, J. F., Reda, M. I., Yaouanq, J., Buhé, T., Brissot, P., Carsin, M., & Deugnier, Y.
Venue
Radiology
Published
1994-11
Volume
193
Issue
2
Pages
533-538
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2058903678
Cited by
225
References
0
FWCI
3.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemochromatosis: diagnosis and quantification of liver iron with gradient-echo MR imaging. https://app.cochat.ai/papers/10.1148/radiology.193.2.7972774
The paper
Gandon, Y., Guyader, D., Heautot, J. F., Reda, M. I., Yaouanq, J., Buhé, T., Brissot, P., Carsin, M., & Deugnier, Y. (1994). Hemochromatosis: diagnosis and quantification of liver iron with gradient-echo MR imaging. Radiology. https://doi.org/10.1148/radiology.193.2.7972774

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.