The DOI matches its Crossref record.
Detection and treatment of dysfunctional hemodialysis access grafts: effect of a surveillance program on graft patency and the incidence of thrombosis.
Abstract
PURPOSE: To determine the value of a hemodialysis graft surveillance program in reducing the incidence of graft thrombosis and prolonging graft patency by means of early detection and percutaneous transluminal angioplasty (PTA) of graft-related stenoses. MATERIALS AND METHODS: For 4-1/2 years, routine graft examination and measurement of several dialysis parameters were used to identify 106 cases of suspected graft dysfunction in 57 patients (56 men, one woman; aged 27-76 years). Graft-related stenoses detected with angiography were treated with PTA. RESULTS: Abnormal physical examination findings were the most common sole indication of graft dysfunction. Of the 106 cases referred for angiographic evaluation, 97 (92%) had at least one lesion. PTA was successful in 88 of 90 treated cases. The primary patency rates at 1 year were 16% for arteriovenous fistulas (AVFs) and 23% for polytetrafluoroethylene (PTFE) grafts. Early detection of stenoses by means of surveillance and repeated PTA enabled 1-year primary assisted patency rates of 67% for AVFs and 68% for PTFE grafts. The incidence of graft thrombosis fell from 48% in 1988 to 17% in 1994 (P < .001). CONCLUSION: The hemodialysis graft surveillance program resulted in a statistically significant reduction in the incidence of graft thrombosis. Although primary patency rates after PTA were low, repeated PTA of detected stenoses allowed good primary assisted patency rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
III. NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: Update 2000
(2001) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(01)70007-8 · Cited by 806
Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutions
Allon, M., & Robbin, M. L. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00551.x · Cited by 763
Vascular access for hemodialysis
Schwab, S. J. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00409.x · Cited by 564
Reporting Standards for Percutaneous Interventions in Dialysis Access
Gray, R. J., Sacks, D., Martin, L. G., & Trerotola, S. O. (2003) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000094618.61428.58 · Cited by 390
Turmel‐Rodrigues, L., Pengloan, J., Baudin, S., Testou, D., Abaza, M., Dahdah, G., Mouton, A., & Blanchard, D. (2000) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/15.12.2029 · Cited by 387
Metadata
- Authors
- Safa, A. A., Valji, K., Roberts, A. C., Ziegler, T. W., Hye, R. J., & Oglevie, S. B.
- Venue
- Radiology
- Published
- 1996-06
- Volume
- 199
- Issue
- 3
- Pages
- 653-657
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2152650409
- Cited by
- 204
- References
- 0
- FWCI
- 21.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and treatment of dysfunctional hemodialysis access grafts: effect of a surveillance program on graft patency and the incidence of thrombosis. https://app.cochat.ai/papers/10.1148/radiology.199.3.8637982
- The paper
- Safa, A. A., Valji, K., Roberts, A. C., Ziegler, T. W., Hye, R. J., & Oglevie, S. B. (1996). Detection and treatment of dysfunctional hemodialysis access grafts: effect of a surveillance program on graft patency and the incidence of thrombosis. Radiology. https://doi.org/10.1148/radiology.199.3.8637982
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.