The DOI matches its Crossref record.
Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs.
Abstract
PURPOSE: To evaluate the effect of a computer-aided diagnosis (CAD) scheme on radiologists' performance in the detection of lung nodules, and to examine a new method of receiver operating characteristic (ROC) analysis. MATERIALS AND METHODS: One hundred twenty radiographs (60 normal and 60 abnormal with lung nodules of varying subtlety) were used. Sixteen radiologists (two thoracic, six general, and eight residents) participated in an observer study in which they read both conventional radiographs and digitized radiographs. The radiologists' performance was evaluated with ROC analysis with two different methods (independent testing and sequential testing) and a continuous rating scale. RESULTS: Az (area under the best fit binormal ROC curve when it is plotted in the unit square) values obtained from ROC analysis with and without CAD output were 0.940 and 0.894, respectively, in the independent test and 0.948 and 0.906, respectively, in the sequential test. Findings with both methods indicated that the CAD scheme statistically significantly improved diagnostic accuracy, particularly for radiologists with less experience (P < .001). Reading time was not increased when CAD was used. CONCLUSION: The CAD scheme can assist radiologists in the detection of lung nodules on chest radiographs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citationAutomation bias: a systematic review of frequency, effect mediators, and mitigators
Goddard, K., Roudsari, A., & Wyatt, J. C. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000089 · Cited by 1,162
Computer-aided diagnosis in chest radiography: a survey
Van Ginneken, B., Ter Haar Romeny, B. M., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974918 · Cited by 516
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Self-citationComputer-aided detection in chest radiography based on artificial intelligence: a survey
Qin, C., Yao, D., Shi, Y., & Song, Z. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0544-y · Cited by 377
Metadata
- Authors
- Kobayashi, T., Xu, X. W., MacMahon, H., Metz, C. E., & Doi, K.
- Venue
- Radiology
- Published
- 1996-06
- Volume
- 199
- Issue
- 3
- Pages
- 843-848
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2013706164
- Cited by
- 244
- References
- 0
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. https://app.cochat.ai/papers/10.1148/radiology.199.3.8638015
- The paper
- Kobayashi, T., Xu, X. W., MacMahon, H., Metz, C. E., & Doi, K. (1996). Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. Radiology. https://doi.org/10.1148/radiology.199.3.8638015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.