The DOI matches its Crossref record.
A receiver operating characteristic partial area index for highly sensitive diagnostic tests.
Abstract
PURPOSE: Area under a receiver operating characteristic (ROC) curve (Az) is widely used as an index of diagnostic performance. However, Az is not a meaningful summary of clinical diagnostic performance when high sensitivity must be maintained clinically. The authors developed a new ROC partial area index, which measures clinical diagnostic performance more meaningfully in such situations, to summarize an ROC curve in only a high-sensitivity region. MATERIALS AND METHODS: The mathematical formation of the partial area index was derived from the conventional binormal model. Statistical tests of apparent differences in this index were formulated analogous to that of Az. One common statistical test involving the partial area index was validated by computer simulations under realistic conditions. RESULTS: An example in mammography illustrates a situation in which the partial area index is more meaningful than Az in measuring clinical diagnostic performance. CONCLUSION: The partial area index can be used as a more meaningful alternative to the conventional Az index for highly sensitive diagnostic tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
Rethinking receiver operating characteristic analysis applications in ecological niche modeling
Peterson, A. T., Papeş, M., & Soberón, J. (2008) · Ecological Modelling · doi:10.1016/j.ecolmodel.2007.11.008 · Cited by 1,526
Receiver operating characteristic curve: overview and practical use for clinicians
Nahm, F. S. (2022) · Korean Journal of Anesthesiology · doi:10.4097/kja.21209 · Cited by 1,484
Receiver Operating Characteristic (ROC) Curve: Practical Review for Radiologists
Park, S. H., Goo, J. M., & Jo, C.-H. (2004) · Korean Journal of Radiology · doi:10.3348/kjr.2004.5.1.11 · Cited by 907
Receiver operating characteristic (ROC) curve for medical researchers
Kumar, R., & Indrayan, A. (2011) · Indian Pediatrics · doi:10.1007/s13312-011-0055-4 · Cited by 872
Metadata
- Authors
- Jiang, Y., Metz, C. E., & Nishikawa, R. M.
- Venue
- Radiology
- Published
- 1996-12
- Volume
- 201
- Issue
- 3
- Pages
- 745-750
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2039408393
- Cited by
- 275
- References
- 0
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A receiver operating characteristic partial area index for highly sensitive diagnostic tests. https://app.cochat.ai/papers/10.1148/radiology.201.3.8939225
- The paper
- Jiang, Y., Metz, C. E., & Nishikawa, R. M. (1996). A receiver operating characteristic partial area index for highly sensitive diagnostic tests. Radiology. https://doi.org/10.1148/radiology.201.3.8939225
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.