The DOI matches its Crossref record.
Proton MR spectroscopy after acute central nervous system injury: outcome prediction in neonates, infants, and children.
Abstract
PURPOSE: To evaluate the usefulness of proton magnetic resonance (MR) spectroscopy in predicting 6-12-month neurologic outcome in children after central nervous system injuries. MATERIALS AND METHODS: Localized single-voxel, 20-msec-echo-time MR spectra (including N-acetylaspartate [NAA], choline [Ch], creatine and phosphocreatine [Cr]) were obtained in the occipital gray matter in 82 patients and 24 control patients. Patient age groups were defined as neonates (< or = 1 month [n = 23]), infants (1-18 months [n = 31]), and children (> or = 18 months [n = 28]). Metabolite ratios and the presence of lactate were determined. Linear discriminant analysis-with admission clinical data, proton MR spectroscopy findings, and MR imaging score (three-point scale based on severity of structural neuroimaging changes)-was performed to help predict outcome in each patient. Findings were then compared with the actual 6-12-month outcome assigned by a pediatric neurologist. RESULTS: Outcome on the basis of proton MR spectroscopy findings combined with clinical data and MR imaging score was predicted correctly in 91% of neonates and in 100% of infants and children. Outcome on the basis of clinical data and MR imaging score alone was 83% in neonates, 84% in infants, and 93% in children. The presence of lactate was significantly higher in patients with poor outcome than in patients with good-moderate outcomes in all three age groups (neonates, 38% vs 5%; infants, 87% vs 5%; children, 64% vs 10% [chi 2 test, P < .02]). In children with poor outcomes, NAA/Cr ratios were significantly lower in infants (P = .006) and children (P < .001), and NAA/Ch ratios were significantly lower in infants (P = .001) and neonates (P = .05). CONCLUSION: Findings at proton MR spectroscopy helped predict long-term neurologic outcomes in children after central nervous system injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic Resonance Spectroscopy
Gujar, S. K., Maheshwari, S., Bj??rkman-Burtscher, I., & Sundgren, P. C. (2005) · Journal of Neuro-Ophthalmology · doi:10.1097/01.wno.0000177307.21081.81 · Cited by 380
Neuroimaging in traumatic brain imaging
Lee, B., & Newberg, A. (2005) · NeuroRX · doi:10.1602/neurorx.2.2.372 · Cited by 345
Pouwels, P. J. W., Brockmann, K., Kruse, B., Wilken, B., Wick, M., Hanefeld, F., & Frahm, J. (1999) · Pediatric Research · doi:10.1203/00006450-199910000-00019 · Cited by 309
Wycliffe, N. D., Holshouser, B. A., & Ashwal, S. (2012) · Swaiman's Pediatric Neurology · doi:10.1016/b978-1-4377-0435-8.00011-1 · Cited by 255
Self-citationShutter, L., Tong, K. A., & Holshouser, B. A. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1693 · Cited by 142
Self-citation
Metadata
- Authors
- Holshouser, B. A., Ashwal, S., Luh, G. Y., Shu, S., Kahlon, S., Auld, K. L., Tomasi, L. G., Perkin, R. M., & Hinshaw, D. B.
- Venue
- Radiology
- Published
- 1997-02
- Volume
- 202
- Issue
- 2
- Pages
- 487-496
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2078147954
- Cited by
- 178
- References
- 0
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proton MR spectroscopy after acute central nervous system injury: outcome prediction in neonates, infants, and children. https://app.cochat.ai/papers/10.1148/radiology.202.2.9015079
- The paper
- Holshouser, B. A., Ashwal, S., Luh, G. Y., Shu, S., Kahlon, S., Auld, K. L., Tomasi, L. G., Perkin, R. M., & Hinshaw, D. B. (1997). Proton MR spectroscopy after acute central nervous system injury: outcome prediction in neonates, infants, and children. Radiology. https://doi.org/10.1148/radiology.202.2.9015079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.