MR imaging of the liver with Resovist: safety, efficacy, and pharmacodynamic properties.
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate the safety, efficacy, and pharmacodynamic properties of a new superparamagnetic parenteral iron oxide contrast agent for magnetic resonance (MR) imaging. MATERIALS AND METHODS: Thirty-six patients with liver lesions received a bolus injection of Resovist (SH U 555 A; Schering, Berlin, Germany) at a dose of 4, 8, or 16 micromol iron per kilogram body weight (micromol Fe/kg). Fast low-angle shot, spin-echo, and turbo gradient spin-echo MR images were obtained before and 10, 40, and 70 minutes after injection. Blood samples were obtained, vital signs were monitored, and adverse events were recorded. Lesion detection was assessed by two independent, blinded readers. RESULTS: No drug-related adverse events occurred. Serum iron and ferritin levels were increased at all dose levels. Partial thromboplastin time increased and factor XI level decreased 4 hours after injection of 16 micromol Fe/kg. Lesion detection and diagnostic confidence were increased in patients who received 4 or 8 micromol Fe/kg, with no further increase with a 16-micromol dose. CONCLUSION: Resovist is safe and effective. The best MR imaging results were obtained 40 minutes after injection of 8 micromol Fe/kg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Reimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Self-citationZaitsev, V. S., Filimonov, D. S., Presnyakov, I. A., Gambino, R. J., & Chu, B. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5993 · Cited by 310
Metadata
- Authors
- Kopp, A. F., Laniado, M., Dammann, F., Stern, W., Grönewäller, E., Balzer, T., Schimpfky, C., & Claussen, C. D.
- Venue
- Radiology
- Published
- 1997-09
- Volume
- 204
- Issue
- 3
- Pages
- 749-756
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2110118058
- Cited by
- 95
- References
- 0
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR imaging of the liver with Resovist: safety, efficacy, and pharmacodynamic properties. https://app.cochat.ai/papers/10.1148/radiology.204.3.9280254
- The paper
- Kopp, A. F., Laniado, M., Dammann, F., Stern, W., Grönewäller, E., Balzer, T., Schimpfky, C., & Claussen, C. D. (1997). MR imaging of the liver with Resovist: safety, efficacy, and pharmacodynamic properties. Radiology. https://doi.org/10.1148/radiology.204.3.9280254
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.