The DOI matches its Crossref record.
MS-325: albumin-targeted contrast agent for MR angiography.
Abstract
PURPOSE: To evaluate the protein-binding and signal enhancement characteristics of MS-325, a gadolinium-based magnetic resonance (MR) imaging blood pool agent that binds to albumin, and compare results with those obtained with existing gadolinium- and iron oxide-based agents. MATERIALS AND METHODS: Protein binding in human plasma was measured by means of ultrafiltration. T1 relaxation times (20 MHz) were measured in human plasma or ex vivo samples from rabbits and monkeys injected with 0.1 mmol of MS-325 per kilogram of body weight. Imaging (three-dimensional fast imaging with steady-state precession, or FISP) was performed at 1.0 T in phantoms, which contained varying concentrations of different agents, or rabbits after injection of 0.015-0.100 mmol/kg MS-325. RESULTS: MS-325 is 80%-96% bound in human plasma and exhibits a relaxivity approximately six to 10 times that of gadolinium diethylenetriaminepentaacetic acid (DTPA). Images of phantoms containing MS-325 were significantly brighter than those containing existing gadolinium chelates or iron particles (monocrystalline iron oxide nanoparticle, or MION) at equivalent concentrations. Findings of in vivo studies indicated strong, persistent plasma T1 reduction with MS-325 for 1 hour (T1 of MS-325, 50-100 msec; T1 of Gd-DTPA, 200-400 msec) and strong vascular enhancement on MR images. CONCLUSION: MS-325 is highly protein bound after injection and provides vascular signal enhancement superior to that provided with other agents. As the first gadolinium-based blood pool agent in human trials, MS-325 has the potential to enhance both dynamic and steady-state MR angiograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parker, D., Dickins, R. S., Puschmann, H., Crossland, C., & Howard, J. A. K. (2002) · Chemical Reviews · doi:10.1021/cr010452+ · Cited by 834
Impact of albumin on drug delivery — New applications on the horizon
Elsadek, B., & Kratz, F. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.09.069 · Cited by 832
Absinta, M., Ha, S.-K., Nair, G., Sati, P., Luciano, N. J., Palisoc, M., Louveau, A., Zaghloul, K. A., Pittaluga, S., Kipnis, J., et al. (2017) · eLife · doi:10.7554/elife.29738 · Cited by 643
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Metadata
- Authors
- Lauffer, R. B., Parmelee, D. J., Dunham, S. U., Ouellet, H. S., Dolan, R. P., Witte, S., McMurry, T. J., & Walovitch, R. C.
- Venue
- Radiology
- Published
- 1998-05
- Volume
- 207
- Issue
- 2
- Pages
- 529-538
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2043638187
- Cited by
- 457
- References
- 0
- Type
- conference abstract
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MS-325: albumin-targeted contrast agent for MR angiography. https://app.cochat.ai/papers/10.1148/radiology.207.2.9577506
- The paper
- Lauffer, R. B., Parmelee, D. J., Dunham, S. U., Ouellet, H. S., Dolan, R. P., Witte, S., McMurry, T. J., & Walovitch, R. C. (1998). MS-325: albumin-targeted contrast agent for MR angiography. Radiology. https://doi.org/10.1148/radiology.207.2.9577506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.