Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record.

Brain: Gadolinium-enhanced Fast Fluid-attenuated Inversion-Recovery MR Imaging

Mathews, Vincent P., Caldemeyer, Karen S., Lowe, Mark J., Greenspan, Stacy L., Weber, David M., Ulmer, John L. · 1999 · Radiology

Abstract

PURPOSE: To determine the clinical utility of gadolinium-enhanced fluid-attenuated inversion-recovery (FLAIR) magnetic resonance (MR) imaging of the brain by comparing results with those at gadolinium-enhanced T1-weighted MR imaging with magnetization transfer (MT) saturation. MATERIALS AND METHODS: In 105 consecutive patients referred for gadolinium-enhanced brain imaging, FLAIR and T1-weighted MR imaging with MT saturation were performed before and after administration of gadopentetate dimeglumine (0.1 mmol per kilogram of body weight). Pre- and postcontrast images were evaluated to determine the presence of abnormal contrast enhancement and whether enhancement was more conspicuous with the FLAIR or T1-weighted sequences. RESULTS: Thirty-nine studies showed intracranial contrast enhancement. Postcontrast T1-weighted images with MT saturation showed superior enhancement in 14 studies, whereas postcontrast fast FLAIR images showed superior enhancement in 15 studies. Four cases demonstrated approximately equal contrast enhancement with both sequences. Six cases showed some areas of enhancement better with T1-weighted imaging with MT saturation and other areas better with postcontrast fast FLAIR imaging. Superficial enhancement was typically better seen with postcontrast fast FLAIR imaging. CONCLUSION: Fast FLAIR images have noticeable T1 contrast making gadolinium-induced enhancement visible. Gadolinium enhancement in lesions that are hyperintense on precontrast FLAIR images, such as intraparenchymal tumors, may be better seen on T1-weighted images than on postcontrast fast FLAIR images. However, postcontrast fast FLAIR images may be useful for detecting superficial abnormalities, such as meningeal disease, because they do not demonstrate contrast enhancement of vessels with slow flow as do T1-weighted images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.211.1.r99mr25257

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Mathews, V. P., Caldemeyer, K. S., Lowe, M. J., Greenspan, S. L., Weber, D. M., & Ulmer, J. L.
Venue
Radiology
Published
1999-04
Volume
211
Issue
1
Pages
257-263
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2129905514
Cited by
210
References
0
FWCI
8.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Brain: Gadolinium-enhanced Fast Fluid-attenuated Inversion-Recovery MR Imaging. https://app.cochat.ai/papers/10.1148/radiology.211.1.r99mr25257
The paper
Mathews, V. P., Caldemeyer, K. S., Lowe, M. J., Greenspan, S. L., Weber, D. M., & Ulmer, J. L. (1999). Brain: Gadolinium-enhanced Fast Fluid-attenuated Inversion-Recovery MR Imaging. Radiology. https://doi.org/10.1148/radiology.211.1.r99mr25257

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.