Left-to-Right Cardiac Shunts: Comparison of Measurements Obtained with MR Velocity Mapping and with Radionuclide Angiography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate the agreement between two noninvasive methods, magnetic resonance (MR) velocity mapping and first-pass radionuclide angiography, to quantify the pulmonary-to-systemic blood flow ratio (QP/QS) in adults, adolescents, and children with left-to-right cardiac shunts. MATERIALS AND METHODS: The accuracy and precision of MR velocity mapping were studied in 12 control subjects (six men, six women) and in a phantom. MR velocity mapping and radionuclide angiography were performed on the same day in 24 patients (16 adults, two adolescents, six children; five male patients, 19 female patients). RESULTS: The mean error in QP/QS at MR velocity mapping in phantom experiments was -1% +/- 1 (mean +/- SD). In control subjects, QP/QS at MR velocity mapping was 1.03 +/- 0.03, and the cardiac index was 3.1 L/min/m2 +/- 0.2 and 3.2 L/min/m2 +/- 0.3 for women and men, respectively. In patients, QP/QS at radionuclide angiography was 14% +/- 13, higher than at MR velocity mapping. Interobserver variability was four times higher for radionuclide angiography compared with MR velocity mapping, 0% + 16 versus 0% +/- 4 (n = 12). The difference between repeated MR flow measurements in the same vessel was -1% +/- 5 (n = 36). CONCLUSION: The data suggest that MR velocity mapping is accurate and precise for measurements of shunt size over the whole range of possible QP/QS values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190811 · Cited by 2,066
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000603 · Cited by 1,602
2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart Disease
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.1029 · Cited by 1,080
2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart Disease: Executive Summary
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.1028 · Cited by 879
Stout, K. K., Daniels, C. J., Aboulhosn, J. A., Bozkurt, B., Broberg, C. S., Colman, J. M., Crumb, S. R., Dearani, J. A., Fuller, S., Gurvitz, M., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000602 · Cited by 533
Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H. (2001) · Circulation · doi:10.1161/01.cir.103.20.2476 · Cited by 309
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Keenan, K. E., Ainslie, M., Barker, A. J., Boss, M. A., Cecil, K. M., Charles, C., Chenevert, T. L., Clarke, L., Evelhoch, J. L., Finn, P., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26982 · Cited by 170
Chernobelsky, A., Shubayev, O., Comeau, C. R., & Wolff, S. D. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640601187588 · Cited by 163
“Phase-contrast CMR can noninvasively and reproducibly quantify blood flow (2, 3, 4) and has been shown to correlate well with radionuclide angiography and invasive oximetry for quantifying left-to-right shunts (5, 6).”
BackgroundCardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
Norton, K. I., Tong, C., Glass, R. B. J., & Nielsen, J. C. (2006) · RadioGraphics · doi:10.1148/rg.261055064 · Cited by 67
Koskenvuo, J. W., Karra, H., Lehtinen, J., Niemi, P., Pärkkä, J., Knuuti, J., & Hartiala, J. J. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00764.x · Cited by 28
Metadata
- Authors
- Arheden, H., Holmqvist, C., Thilen, U., Hanséus, K., Björkhem, G., Pahlm, O., Laurin, S., & Ståhlberg, F.
- Venue
- Radiology
- Published
- 1999-05
- Volume
- 211
- Issue
- 2
- Pages
- 453-458
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2087425159
- Cited by
- 66
- References
- 1
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.