Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Diagnosis and Staging of Ovarian Cancer: Comparative Values of Doppler and Conventional US, CT, and MR Imaging Correlated with Surgery and Histopathologic Analysis—Report of the Radiology Diagnostic Oncology Group

Kurtz, Alfred B., Tsimikas, John V., Tempany, Clare M. C., Hamper, Ulrike M., Arger, Peter H., Bree, Robert L., Wechsler, Richard J., Francis, Isaac R., Kuhlman, Janet E., Siegelman, Evan S., Mitchell, Donald G., Silverman, Stuart G., Brown, Douglas L., Sheth, Sheila, Coleman, Beverly G., Ellis, James H., Kurman, Robert J., Caudry, Daryl J., McNeil, Barbara J.·1999·Radiology

Abstract

PURPOSE: To determine the optimal imaging modality for diagnosis and staging of ovarian cancer. MATERIALS AND METHODS: Two hundred eighty women suspected to have ovarian cancer were enrolled in a prospective study before surgery. Doppler ultrasonography (US), computed tomography (CT), and magnetic resonance (MR) imaging were used to evaluate the mass; conventional US, CT, and MR imaging were used to stage spread. RESULTS: All three modalities had high accuracy (0.91) for the overall diagnosis of malignancy. In the ovaries, the accuracy of MR imaging (0.91) was higher than that of CT and significantly higher than that of Doppler US (0.78). In the extraovarian pelvis and in the abdomen, conventional US, CT, and MR imaging had similar accuracies (0.87-0.95). In differentiation of disease confined to the pelvis from abdominal spread, the specificity of conventional US (96%) was higher than that of CT and significantly higher than that of MR imaging (88%), whereas the sensitivities of MR imaging (98%) and CT (92%) were significantly higher than that of conventional US (75%). CONCLUSION: MR imaging is superior to Doppler US and CT in diagnosis of malignant ovarian masses. There is little variation among conventional US, CT, and MR imaging as regards staging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.212.1.r99jl3619

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 267

Metadata

Authors
Kurtz, A. B., Tsimikas, J. V., Tempany, C. M. C., Hamper, U. M., Arger, P. H., Bree, R. L., Wechsler, R. J., Francis, I. R., Kuhlman, J. E., Siegelman, E. S., Mitchell, D. G., Silverman, S. G., Brown, D. L., Sheth, S., Coleman, B. G., Ellis, J. H., Kurman, R. J., Caudry, D. J., & McNeil, B. J.
Venue
Radiology
Published
1999-07
Volume
212
Issue
1
Pages
19-27
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2044313164
Cited by
267
References
17
FWCI
8.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis and Staging of Ovarian Cancer: Comparative Values of Doppler and Conventional US, CT, and MR Imaging Correlated with Surgery and Histopathologic Analysis—Report of the Radiology Diagnostic Oncology Group. https://app.cochat.ai/papers/10.1148/radiology.212.1.r99jl3619
The paper
Kurtz, A. B., Tsimikas, J. V., Tempany, C. M. C., Hamper, U. M., Arger, P. H., Bree, R. L., Wechsler, R. J., Francis, I. R., Kuhlman, J. E., Siegelman, E. S., Mitchell, D. G., Silverman, S. G., Brown, D. L., Sheth, S., Coleman, B. G., Ellis, J. H., Kurman, R. J., Caudry, D. J., & McNeil, B. J. (1999). Diagnosis and Staging of Ovarian Cancer: Comparative Values of Doppler and Conventional US, CT, and MR Imaging Correlated with Surgery and Histopathologic Analysis—Report of the Radiology Diagnostic Oncology Group. Radiology. https://doi.org/10.1148/radiology.212.1.r99jl3619

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.