CoChat

MR Imaging and Histologic Features of Subinsular Bright Spots on T2-weighted MR Images: Virchow-Robin Spaces of the Extreme Capsule and Insular Cortex

Song, Chang June, Kim, Jung H., Kier, E. Leon, Bronen, Richard A. · 2000 · Radiology
Cited by 83

The DOI matches its Crossref record.

Abstract

PURPOSE: To determine the cause and frequency of high-signal-intensity foci detected in the insular cortex and extreme capsule on thin-section, high-spatial-resolution, coronal, T2-weighted magnetic resonance (MR) images. MATERIALS AND METHODS: The authors assessed high-signal-intensity areas in the insular cortex and extreme capsule on coronal MR images obtained in 56 patients with seizure and five control subjects. Images were obtained with thin-section, high-spatial-resolution, T2-weighted, fast spin-echo; three-dimensional, spoiled gradient-recalled-echo; and fluid-attenuated inversion-recovery sequences. In two formalin-fixed brain specimens, MR imaging findings were correlated with gross anatomic and histologic findings. RESULTS: Subinsular bright spots were found in 53 of the 56 (95%) patients (96 of 112 [86%] hemispheres) and all five control subjects. The spots were elliptical in 30 patients, round in 14 patients, linear in 22 patients, and dotlike in seven patients and often had a featherlike configuration. The spots were isointense to cerebrospinal fluid on T2-weighted, fast SE images and were located in the anterior extreme capsule white matter and insular cortex. MR imaging of brain specimens revealed bilateral elliptical areas of high signal intensity that corresponded to small multiple cavities at gross anatomic inspection. At microscopic examination, these cavities were perivascular spaces of mostly arteriolar origin. CONCLUSION: High-signal-intensity subinsular foci at MR imaging are due to enlarged perivascular spaces. In most cases, these foci can be visualized on thin-section, high-spatial-resolution, coronal T2-weighted images; they should not be mistaken for pathologic conditions when they occur unilaterally.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.214.3.r00mr17671

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
Song, C. J., Kim, J. H., Kier, E. L., & Bronen, R. A.
Venue
Radiology
Published
2000-03
Volume
214
Issue
3
Pages
671-677
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1975228314
Cited by
83
References
0
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR Imaging and Histologic Features of Subinsular Bright Spots on T2-weighted MR Images: Virchow-Robin Spaces of the Extreme Capsule and Insular Cortex. https://app.cochat.ai/papers/10.1148/radiology.214.3.r00mr17671
The paper
Song, C. J., Kim, J. H., Kier, E. L., & Bronen, R. A. (2000). MR Imaging and Histologic Features of Subinsular Bright Spots on T2-weighted MR Images: Virchow-Robin Spaces of the Extreme Capsule and Insular Cortex. Radiology. https://doi.org/10.1148/radiology.214.3.r00mr17671

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.