Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 248

The DOI matches its Crossref record.

Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography

Rubin, Geoffrey D., Shiau, Maria C., Leung, Ann N., Kee, Stephen T., Logan, Laura J., Sofilos, Mark C. · 2000 · Radiology

Abstract

PURPOSE: To compare single- versus four-channel helical computed tomographic (CT) aortography. MATERIALS AND METHODS: Forty-eight patients with aortic aneurysm or dissection underwent four- and one-channel CT angiography. Scan pairs covered the thoracic inlet to the diaphragm (n = 10) and supraceliac abdominal aorta (n = 19) or thoracic inlet (n = 19) to the femoral arterial bifurcations. For four-channel CT, nominal section thickness and pitch were 2.5 mm and 6.0, respectively, and for one-channel CT, 3.0 mm and 2.0 to the infrarenal aorta and 5.0 mm and 2.0 to the femoral arteries. Effective section thickness, scanning duration, scanning coverage, dose of iodinated contrast material, and mean aortoiliac attenuation were compared. Data were summarized as speed (coverage/duration), scanning efficiency (speed/section thickness), and contrast efficiency (mean aortic attenuation/dose of contrast material). RESULTS: At four- versus one-channel CT, CT angiography was 2.6 times faster, scanning efficiency was 4.1 times greater, contrast efficiency was 2.5 times greater, dose of contrast material was reduced (mean, 57%; 97 vs 232 mL) without a significant change in aortic enhancement, and sections were thinner (mean, 40%; 3.2 vs 5.3 mm) despite a 59% shorter scanning duration (22 vs 56 seconds). CONCLUSION: Substantially reduced doses of contrast medium, shorter scanning durations, and narrower effective sections result with four- versus one-channel CT aortography. No advantages of one-channel CT aortography were demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.215.3.r00jn18670

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 248

Metadata

Authors
Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C.
Venue
Radiology
Published
2000-06
Volume
215
Issue
3
Pages
670-676
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1967246654
Cited by
248
References
0
FWCI
23.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography. https://app.cochat.ai/papers/10.1148/radiology.215.3.r00jn18670
The paper
Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C. (2000). Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography. Radiology. https://doi.org/10.1148/radiology.215.3.r00jn18670

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.