The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience
Abstract
PURPOSE: To assess the patterns of lower extremity arterial inflow and runoff opacification with four-channel multi-detector row computed tomographic (CT) angiography in a cohort of patients with disease warranting imaging of the lower extremity arterial system. MATERIALS AND METHODS: Twenty-four patients with symptomatic lower extremity arterial occlusive or aneurysmal disease underwent imaging with four-channel multi-detector row CT from the supraceliac abdominal aorta through the feet. Transverse sections were acquired with a 2.5-mm nominal detector width and pitch of 6.0 (3.2-mm effective section thickness) following intravenous injection of 174-185 mL of iodinated contrast medium (300 mg iodine per milliliter). In each patient, attenuation measurements were recorded in 16 arterial and 16 venous locations. In 18 patients, two radiologists assessed the detectability and stenosis degree of 21 arterial segments per patient relative to these features at conventional angiography. RESULTS: A mean scanning time of 66 seconds was required to cover a mean of 1,233 mm, resulting in a mean of 908 transverse reconstructions. All 504 arterial segments were depicted and analyzable. Mean arterial attenuation ranged from 253 HU in the midabdominal aorta to 357 HU in the popliteal artery and 253 HU in the dorsalis pedis or posterior tibial artery measured inferior to the tibiotalar joint. Maximum mean venous enhancement (99 HU) was observed in the saphenous vein at the ankle, with all other venous stations measuring less than 74 HU. CONCLUSION: The arteries of lower extremity inflow and runoff can be reliably depicted with minimal venous enhancement by using multi-detector row CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LENG, G. C., LEE, A. J., FOWKERS, F. G. R., WHITEMAN, M., DUNBAR, J., HOUSLEY, E., & RUCKLEY, C. V. (1996) · International Journal of Epidemiology · doi:10.1093/ije/25.6.1172 · Cited by 667
Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.
Rubin, G. D., Dake, M. D., Napel, S. A., McDonnell, C. H., & Jeffrey, R. B. (1993) · Radiology · doi:10.1148/radiology.186.1.8416556 · Cited by 362
Self-citationPentecost, M. J., Criqui, M. H., Dorros, G., Goldstone, J., Johnston, K. W., Martin, E. C., Ring, E. J., & Spies, J. B. (1994) · Circulation · doi:10.1161/01.cir.89.1.511 · Cited by 303
Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography.
Ho, K. Y., Leiner, T., de Haan, M. W., Kessels, A. G., Kitslaar, P. J., & van Engelshoven, J. M. (1998) · Radiology · doi:10.1148/radiology.206.3.9494486 · Cited by 301
Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography
Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn18670 · Cited by 248
Self-citationData explosion: the challenge of multidetector-row CT
Rubin, G. D. (2000) · European Journal of Radiology · doi:10.1016/s0720-048x(00)00270-9 · Cited by 208
Self-citationRuehm, S. G., Hany, T. F., Pfammatter, T., Schneider, E., Ladd, M., & Debatin, J. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1741127 · Cited by 177
Aortic Aneurysmal Disease: Assessment of Stent-Graft Treatment—CT versus Conventional Angiography
Armerding, M. D., Rubin, G. D., Beaulieu, C. F., et al. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap28138 · Cited by 176
Self-citationMR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease
Rofsky, N. M., & Adelman, M. A. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe42325 · Cited by 136
Cost Identification of Abdominal Aortic Aneurysm Imaging by Using Time and Motion Analyses
Rubin, G. D., Armerding, M. D., Dake, M. D., & Napel, S. A. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap4863 · Cited by 45
Self-citation
Cited by
Atherosclerotic Vascular Disease Conference: Writing Group III: Pathophysiology
Faxon, D. P., Fuster, V., Libby, P., Beckman, J. A., Hiatt, W. R., Thompson, R. W., Topper, J. N., Annex, B. H., Rundback, J. H., Fabunmi, R. P., et al. (2004) · Circulation · doi:10.1161/01.cir.0000128520.37674.ef · Cited by 414
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Peripheral Artery Disease: Current Insight Into the Disease and Its Diagnosis and Management
Olin, J. W., & Sealove, B. A. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2010.0133 · Cited by 349
Metadata
- Authors
- Rubin, G. D., Schmidt, A. J., Logan, L. J., & Sofilos, M. C.
- Venue
- Radiology
- Published
- 2001-10
- Volume
- 221
- Issue
- 1
- Pages
- 146-158
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2053413474
- Cited by
- 302
- References
- 10
- FWCI
- 16.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience. https://app.cochat.ai/papers/10.1148/radiol.2211001325
- The paper
- Rubin, G. D., Schmidt, A. J., Logan, L. J., & Sofilos, M. C. (2001). Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience. Radiology. https://doi.org/10.1148/radiol.2211001325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.