Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience

Rubin, Geoffrey D., Schmidt, Andrew J., Logan, Laura J., Sofilos, Mark C.·2001·Radiology

Abstract

PURPOSE: To assess the patterns of lower extremity arterial inflow and runoff opacification with four-channel multi-detector row computed tomographic (CT) angiography in a cohort of patients with disease warranting imaging of the lower extremity arterial system. MATERIALS AND METHODS: Twenty-four patients with symptomatic lower extremity arterial occlusive or aneurysmal disease underwent imaging with four-channel multi-detector row CT from the supraceliac abdominal aorta through the feet. Transverse sections were acquired with a 2.5-mm nominal detector width and pitch of 6.0 (3.2-mm effective section thickness) following intravenous injection of 174-185 mL of iodinated contrast medium (300 mg iodine per milliliter). In each patient, attenuation measurements were recorded in 16 arterial and 16 venous locations. In 18 patients, two radiologists assessed the detectability and stenosis degree of 21 arterial segments per patient relative to these features at conventional angiography. RESULTS: A mean scanning time of 66 seconds was required to cover a mean of 1,233 mm, resulting in a mean of 908 transverse reconstructions. All 504 arterial segments were depicted and analyzable. Mean arterial attenuation ranged from 253 HU in the midabdominal aorta to 357 HU in the popliteal artery and 253 HU in the dorsalis pedis or posterior tibial artery measured inferior to the tibiotalar joint. Maximum mean venous enhancement (99 HU) was observed in the saphenous vein at the ankle, with all other venous stations measuring less than 74 HU. CONCLUSION: The arteries of lower extremity inflow and runoff can be reliably depicted with minimal venous enhancement by using multi-detector row CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2211001325

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 302

Metadata

Authors
Rubin, G. D., Schmidt, A. J., Logan, L. J., & Sofilos, M. C.
Venue
Radiology
Published
2001-10
Volume
221
Issue
1
Pages
146-158
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2053413474
Cited by
302
References
10
FWCI
16.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience. https://app.cochat.ai/papers/10.1148/radiol.2211001325
The paper
Rubin, G. D., Schmidt, A. J., Logan, L. J., & Sofilos, M. C. (2001). Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience. Radiology. https://doi.org/10.1148/radiol.2211001325

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.