Left Ventricular Mass and Volume: Fast Calculation with Guide-Point Modeling on MR Images
The DOI matches its Crossref record.
Abstract
The authors describe a fast method for calculating left ventricle (LV) mass and volumes from multiplanar magnetic resonance (MR) images. Mathematic models were fitted to a small number of user-selected guide points in 15 healthy volunteers, 13 patients after myocardial infarction, and a canine model of mitral regurgitation in eight dogs. Errors between model and manual contours were small (LV mass, 1.8 g +/- 4.9 [mean +/- SD]; end-diastolic volume, 2.2 mL +/- 4.6; end-systolic volume, 2.3 mL +/- 3.8). Estimates of global function could be obtained in 6 minutes, a time saving of 5-10 times over estimates with manual contouring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fonseca, C. G., Backhaus, M., Bluemke, D. A., Britten, R. D., Chung, J. D., Cowan, B. R., Dinov, I. D., Finn, J. P., Hunter, P. J., Kadish, A. H., et al. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr360 · Cited by 280
Self-citationPlein, S., Bloomer, T. N., Ridgway, J. P., Jones, T. R., Bainbridge, G. J., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1178 · Cited by 257
Hollingsworth, K. G. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/r297 · Cited by 238
“…the acquisition by using a combination of CS-PI and partial Fourier encoding, but also reduces the number of cardiac slices to be acquired to 7 (4 non-contiguous short axis sections spread over the left ventricle and 3 long axis sections) by using an imposed guide-point model (Young et al 2000).”
MethodCardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Suinesiaputra, A., Cowan, B. R., Al-Agamy, A. O., Elattar, M. A., Ayache, N., Fahmy, A. S., Khalifa, A. M., Medrano-Gracia, P., Jolly, M.-P., Kadish, A. H., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.09.001 · Cited by 206
Self-citationBrown, J., Jenkins, C., & Marwick, T. H. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.08.032 · Cited by 193
Hueper, K., Vogel-Claussen, J., Parikh, M. A., Austin, J. H. M., Bluemke, D. A., Carr, J., Choi, J., Goldstein, T. A., Gomes, A. S., Hoffman, E. A., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201411-2120oc · Cited by 179
Kawel, N., Nacif, M., Zavodni, A., Jones, J., Liu, S., Sibley, C. T., & Bluemke, D. A. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-27 · Cited by 179
Modelling passive diastolic mechanics with quantitative MRI of cardiac structure and function
Wang, V. Y., Lam, H. I., Ennis, D. B., Cowan, B. R., Young, A. A., & Nash, M. P. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.006 · Cited by 177
“9b) images with the aid of a guide-point model (Young et al., 2000) at each frame (60 frames per cardiac cycle).”
MethodSelf-citationMulti-atlas segmentation with augmented features for cardiac MR images
Bai, W., Shi, W., Ledig, C., & Rueckert, D. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.09.005 · Cited by 159
“The segmentation of the myocardium was carried out for all the temporal frames with the guide-point modelling approach in which most of input was manual (Young et al., 2000; Li et al., 2010).”
BackgroundMethodMedrano-Gracia, P., Cowan, B. R., Ambale-Venkatesh, B., Bluemke, D. A., Eng, J., Finn, J. P., Fonseca, C. G., Lima, J. A., Suinesiaputra, A., & Young, A. A. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0056-2 · Cited by 98
Self-citationImage-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Metadata
- Authors
- Young, A. A., Cowan, B. R., Thrupp, S. F., Hedley, W. J., & Dell’Italia, L. J.
- Venue
- Radiology
- Published
- 2000-08
- Volume
- 216
- Issue
- 2
- Pages
- 597-602
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2341196897
- Cited by
- 205
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.