Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 579

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation

Yankelevitz, David F., Reeves, Anthony P., Kostis, William J., Zhao, Binsheng, Henschke, Claudia I.·2000·Radiology

Abstract

PURPOSE: To determine the accuracy of high-resolution computed tomographic (CT) volumetric measurements of small pulmonary nodules to assess growth and malignancy status. MATERIALS AND METHODS: The accuracy of three-dimensional (3D) image extraction and isotropic resampling techniques was assessed by performing three experiments. The first experiment measured volumes in spherical synthetic nodules of two diameters (3.20 and 3.96 mm), the second measured deformable silicone synthetic nodules prior to and after their shape had been altered markedly, and the third measured nodules of various shapes and sizes. Three-dimensional techniques were used to assess growth in 13 patients for whom the final diagnosis was known and whose initial nodule diameters were less than 10 mm. By using the exponential growth model and the calculated nodule volume at two points in time, the doubling time for each subject was calculated. RESULTS: The three synthetic nodule studies revealed that the volume could be measured accurately to within +/-3%. All five malignant nodules grew, and all had doubling times less than 177 days. Some malignant nodules had asymmetric patterns of growth identified by using the 3D techniques but not the two-dimensional methods. All eight benign nodules had doubling times of 396 days or greater or showed a decrease in volume. CONCLUSION: CT volumetric measurements are highly accurate for determining volume and are useful in assessing growth of small nodules and calculating their doubling times.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.217.1.r00oc33251

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 579

Metadata

Authors
Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B., & Henschke, C. I.
Venue
Radiology
Published
2000-10
Volume
217
Issue
1
Pages
251-256
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2158303110
Cited by
579
References
5
FWCI
22.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation. https://app.cochat.ai/papers/10.1148/radiology.217.1.r00oc33251
The paper
Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B., & Henschke, C. I. (2000). Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation. Radiology. https://doi.org/10.1148/radiology.217.1.r00oc33251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.