Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the accuracy of high-resolution computed tomographic (CT) volumetric measurements of small pulmonary nodules to assess growth and malignancy status. MATERIALS AND METHODS: The accuracy of three-dimensional (3D) image extraction and isotropic resampling techniques was assessed by performing three experiments. The first experiment measured volumes in spherical synthetic nodules of two diameters (3.20 and 3.96 mm), the second measured deformable silicone synthetic nodules prior to and after their shape had been altered markedly, and the third measured nodules of various shapes and sizes. Three-dimensional techniques were used to assess growth in 13 patients for whom the final diagnosis was known and whose initial nodule diameters were less than 10 mm. By using the exponential growth model and the calculated nodule volume at two points in time, the doubling time for each subject was calculated. RESULTS: The three synthetic nodule studies revealed that the volume could be measured accurately to within +/-3%. All five malignant nodules grew, and all had doubling times less than 177 days. Some malignant nodules had asymmetric patterns of growth identified by using the 3D techniques but not the two-dimensional methods. All eight benign nodules had doubling times of 396 days or greater or showed a decrease in volume. CONCLUSION: CT volumetric measurements are highly accurate for determining volume and are useful in assessing growth of small nodules and calculating their doubling times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Self-citationComputerized Detection of Pulmonary Nodules on CT Scans
Armato, S. G., Giger, M. L., Moran, C. J., Blackburn, J. T., Doi, K., & MacMahon, H. (1999) · Radiographics · doi:10.1148/radiographics.19.5.g99se181303 · Cited by 380
Management of solitary pulmonary nodules
Lillington, G. A. (1991) · Disease-a-Month · doi:10.1016/s0011-5029(05)80012-4 · Cited by 140
Harris, K. M., Adams, H., Lloyd, D. C. F., & Harvey, D. J. (1993) · Clinical Radiology · doi:10.1016/s0009-9260(05)81130-4 · Cited by 81
Management of solitary pulmonary nodules: How to decide when resection is required
Lillington, G. A. (1997) · Postgraduate Medicine · doi:10.3810/pgm.1997.03.177 · Cited by 68
Cited by
Travis, W. D., Brambilla, E., Noguchi, M., Nicholson, A. G., Geisinger, K. R., Yatabe, Y., Beer, D. G., Powell, C. A., Riely, G. J., Van Schil, P. E., et al. (2011) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318206a221 · Cited by 4,792
Callister, M. E. J., Baldwin, D. R., Akram, A. R., Barnard, S., Cane, P., Draffan, J., Franks, K., Gleeson, F., Graham, R., Malhotra, P., et al. (2015) · Thorax · doi:10.1136/thoraxjnl-2015-207168 · Cited by 958
Clinical biomarkers in drug discovery and development
Frank, R., & Hargreaves, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1130 · Cited by 794
Travis, W. D., Asamura, H., Bankier, A. A., Beasley, M. B., Detterbeck, F., Flieder, D. B., Goo, J. M., MacMahon, H., Naidich, D., Nicholson, A. G., et al. (2016) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.03.025 · Cited by 722
Computed Tomography Screening and Lung Cancer Outcomes
Bach, P. B. (2007) · JAMA · doi:10.1001/jama.297.9.953 · Cited by 567
Erasmus, J. J., Gladish, G. W., Broemeling, L., Sabloff, B. S., Truong, M. T., Herbst, R. S., & Munden, R. F. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.01.144 · Cited by 476
Mulshine, J. L., & Sullivan, D. C. (2005) · New England Journal of Medicine · doi:10.1056/nejmcp042630 · Cited by 419
Nodule management protocol of the NELSON randomised lung cancer screening trial
Xu, D. M., Gietema, H., de Koning, H., Vernhout, R., Nackaerts, K., Prokop, M., Weenink, C., Lammers, J.-W., Groen, H., Oudkerk, M., et al. (2006) · Lung Cancer · doi:10.1016/j.lungcan.2006.08.006 · Cited by 347
Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable?
Revel, M.-P., Bissery, A., Bienvenu, M., Aycard, L., Lefort, C., & Frija, G. (2004) · Radiology · doi:10.1148/radiol.2312030167 · Cited by 345
Lung Cancer Screening Using Low-Dose Spiral CT
Nawa, T., Nakagawa, T., Kusano, S., Kawasaki, Y., Sugawara, Y., & Nakata, H. (2002) · Chest · doi:10.1378/chest.122.1.15 · Cited by 315
Field, J. K., Duffy, S. W., Baldwin, D. R., Brain, K. E., Devaraj, A., Eisen, T., Green, B. A., Holemans, J. A., Kavanagh, T., Kerr, K. M., et al. (2016) · Health Technology Assessment · doi:10.3310/hta20400 · Cited by 296
Godoy, M. C. B., & Naidich, D. P. (2009) · Radiology · doi:10.1148/radiol.2533090179 · Cited by 294
Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Texture Feature Analysis for Computer-Aided Diagnosis on Pulmonary Nodules
Han, F., Wang, H., Zhang, G., Han, H., Song, B., Li, L., Moore, W., Lu, H., Zhao, H., & Liang, Z. (2015) · Journal of Digital Imaging · doi:10.1007/s10278-014-9718-8 · Cited by 265
NELSON lung cancer screening study
Ru Zhao, Y., Xie, X., de Koning, H. J., Mali, W. P., Vliegenthart, R., & Oudkerk, M. (2011) · Cancer Imaging · doi:10.1102/1470-7330.2011.9020 · Cited by 249
“Volumetric 3D measurements have been found to be more accurate than 2D evaluation of pulmonary nodules([16,17]).”
BackgroundLung Cancer—Where Are We Today?: Current Advances in Staging and Nonsurgical Treatment
Spiro, S. G., & Porter, J. C. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200202-070so · Cited by 249
Radiologic Measurements of Tumor Response to Treatment: Practical Approaches and Limitations
Suzuki, C., Jacobsson, H., Hatschek, T., Torkzad, M. R., Bodén, K., Eriksson-Alm, Y., Berg, E., Fujii, H., Kubo, A., & Blomqvist, L. (2008) · RadioGraphics · doi:10.1148/rg.282075068 · Cited by 236
On measuring the change in size of pulmonary nodules
Reeves, A. P., Chan, A. B., Yankelevitz, D. F., Henschke, C. I., Kressler, B., & Kostis, W. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871548 · Cited by 216
“D algorithms for size and growth characterization [1], [6], [14], as growth is the parameter most associated with malignancy .”
BackgroundMethodInfluentialSelf-citationLung Cancers Diagnosed at Annual CT Screening: Volume Doubling Times
Henschke, C. I., Yankelevitz, D. F., Yip, R., Reeves, A. P., Farooqi, A., Xu, D., Smith, J. P., Libby, D. M., Pasmantier, M. W., & Miettinen, O. S. (2012) · Radiology · doi:10.1148/radiol.12102489 · Cited by 208
Self-citationKostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C., & Henschke, C. I. (2004) · Radiology · doi:10.1148/radiol.2312030553 · Cited by 206
Self-citationManaging the Small Pulmonary Nodule Discovered by CT
Libby, D. M., Smith, J. P., Altorki, N. K., Pasmantier, M. W., Yankelevitz, D., & Henschke, C. I. (2004) · Chest · doi:10.1378/chest.125.4.1522 · Cited by 202
Self-citationLung nodules: size still matters
Larici, A. R., Farchione, A., Franchi, P., Ciliberto, M., Cicchetti, G., Calandriello, L., del Ciello, A., & Bonomo, L. (2017) · European Respiratory Review · doi:10.1183/16000617.0025-2017 · Cited by 201
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Clinical and Organizational Factors in the Initial Evaluation of Patients With Lung Cancer
Ost, D. E., Jim Yeung, S.-C., Tanoue, L. T., & Gould, M. K. (2013) · Chest · doi:10.1378/chest.12-2352 · Cited by 195
The Cost-Effectiveness of Low-Dose CT Screening for Lung Cancer*
Wisnivesky, J. P., Mushlin, A. I., Sicherman, N., & Henschke, C. (2003) · Chest · doi:10.1378/chest.124.2.614 · Cited by 184
Self-citationSchaefer, J. F., Vollmar, J., Schick, F., Vonthein, R., Seemann, M. D., Aebert, H., Dierkesmann, R., Friedel, G., & Claussen, C. D. (2004) · Radiology · doi:10.1148/radiol.2322030515 · Cited by 179
“A current acceptable approach is frequent CT follow-up to determine the growth rate through an increase in volume (4,7,8).”
Kakinuma, R., Ohmatsu, H., Kaneko, M., Kusumoto, M., Yoshida, J., Nagai, K., Nishiwaki, Y., Kobayashi, T., Tsuchiya, R., Nishiyama, H., et al. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200401000-00003 · Cited by 163
Estimating Overdiagnosis in Low-Dose Computed Tomography Screening for Lung Cancer: A Cohort Study
Veronesi, G., Maisonneuve, P., Bellomi, M., Rampinelli, C., Durli, I., Bertolotti, R., & Spaggiari, L. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-11-201212040-00005 · Cited by 162
“If the software was unable to estimate volume (for example, for juxtapleural or juxtavascular lesions, or nonsolid nodules not recognized by the software), an electronic caliper was used to measure the largest axial diameter and the following formula was applied to determine the VDT (24):”
BackgroundMethodMarten, K., Auer, F., Schmidt, S., Kohl, G., Rummeny, E. J., & Engelke, C. (2006) · European Radiology · doi:10.1007/s00330-005-0036-x · Cited by 162
“In phantom studies and preliminary clinical settings, automated volumetry has been demonstrated to produce minimal errors, thus maintaining very high measurement reproducibility [6, 7, 20].”
Backgroundde Hoop, B., Gietema, H., van Ginneken, B., Zanen, P., Groenewegen, G., & Prokop, M. (2009) · European Radiology · doi:10.1007/s00330-008-1229-x · Cited by 159
“They are the major radiographic indicator of lung cancer and metastatic disease, despite the fact that most of them are caused by benign conditions [1–3].”
BackgroundMethodRios Velazquez, E., Aerts, H. J. W. L., Gu, Y., Goldgof, D. B., De Ruysscher, D., Dekker, A., Korn, R., Gillies, R. J., & Lambin, P. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.09.023 · Cited by 120
“In this regard, automatic methods to interpret chest CT images have largely focused on the early detection of lung nodules [34,35], on the differential diagnosis of malignant versus benign nodules [36] and in the measurement of nodule or tumor size as treatment response criteria [37,38].”
Method
Metadata
- Authors
- Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B., & Henschke, C. I.
- Venue
- Radiology
- Published
- 2000-10
- Volume
- 217
- Issue
- 1
- Pages
- 251-256
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2158303110
- Cited by
- 579
- References
- 5
- FWCI
- 22.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.