Electromagnetic Heating of Breast Tumors in Interventional Radiology: In Vitro and in Vivo Studies in Human Cadavers and Mice
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess relevant parameters for the minimally invasive elimination of breast tumors by using a selective application of magnetite and exposure of the breast to an alternating magnetic field. MATERIALS AND METHODS: The specific absorption rate (SAR) of different magnetite samples was determined calorimetrically. Temperature elevations based on magnetite mass (7-112 mg) and magnetic field amplitude (1.2-6.5 kA/m frequency, 400 kHz) were investigated by using human breast tissue. Parameter combinations (21 mg +/- 9 [SD], 242-second magnetic field exposure, 6.5-kA/m amplitude) were tested in 10 immunodeficient mice bearing human adenocarcinomas (MX-1 cells). Histologic sections of heated tumor tissue were analyzed. RESULTS: SAR data of different magnetite particle types ranged from 3 to 211 W/g. Temperature elevation (DeltaT) as a function of the magnetite mass increased linearly up to 28 mg; at higher masses, a saturation of DeltaT was observed at nearly 88 degrees C. The dependence of DeltaT on magnetic field amplitude (H) revealed a third-order power law: DeltaT = 0.26 degrees C/(kA/m)(3). H(3), with r(2) = 0.95. A mean temperature of 71 degrees C +/- 8 was recorded in the tumor region at the end of magnetic field exposure of the mice. Typical macroscopic findings included tumor shrinkage after heating. Histologically nuclear degenerations were observed in heated malignant cells. CONCLUSION: Magnetic heating of breast tumors is a promising technique for future interventional radiologic treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boring, C. C., Squires, T. S., Tong, T., & Montgomery, S. (1994) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.44.1.7 · Cited by 1,315
Selective Inductive Heating of Lymph Nodes
GILCHRIST, R. K., MEDAL, R., SHOREY, W. D., HANSELMAN, R. C., PARROTT, J. C., & TAYLOR, C. B. (1957) · Annals of Surgery · doi:10.1097/00000658-195710000-00007 · Cited by 1,091
Physical limits of hyperthermia using magnetite fine particles
Hergt, R., Andra, W., d'Ambly, C. G., Hilger, I., Kaiser, W. A., Richter, U., & Schmidt, H.-G. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.718537 · Cited by 658
Self-citationLübbe, A. S., Bergemann, C., Riess, H. B., Schriever, F., Reichardt, P., Possinger, K., Matthias, M., Dörken, B., Herrmann, F., Gürtler, R., et al. (1996) · PubMed · Cited by 652
Usable Frequencies in Hyperthermia with Thermal Seeds
Atkinson, W. J., Brezovich, I. A., & Chakraborty, D. P. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325372 · Cited by 496
Tannock, I. F., Hill, R. P., & Carey, R. W. (1989) · Plastic and Reconstructive surgery · doi:10.1097/00006534-198905000-00037 · Cited by 473
Application of magnetite ferrofluids for hyperthermia
Hiergeist, R., Andrä, W., Buske, N., Hergt, R., Hilger, I., Richter, U., & Kaiser, W. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00145-6 · Cited by 385
Self-citationEffects of Magnetic Fluid Hyperthermia (MFH) on C3H mammary carcinoma in vivo
Jordan, A., Scholz, R., Wust, P., Fähling, H., Krause, J., Wlodarczyk, W., Sander, B., Vogl, T., & Felix, R. (1997) · International Journal of Hyperthermia · doi:10.3109/02656739709023559 · Cited by 325
C.F. Chan, D., B. Kirpotin, D., & A. Bunn, P. (1993) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(93)91113-l · Cited by 319
Gordon, R. T., Hines, J. R., & Gordon, D. (1979) · Medical Hypotheses · doi:10.1016/0306-9877(79)90063-x · Cited by 310
Andrä, W., d'Ambly, C. G., Hergt, R., Hilger, I., & Kaiser, W. A. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00552-6 · Cited by 226
Self-citationGlobal breast cancer mortality statistics
Mettlin, C. (1999) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.49.3.138 · Cited by 187
Observations on the Use of Ferromagnetic Implants for Inducing Hyperthermia
Stauffer, P. R., Cetas, T. C., Fletcher, A. M., Deyoung, D. W., Dewhirst, M. W., Oleson, J. R., & Roemer, R. B. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325373 · Cited by 166
Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.4.771 · Cited by 122
Development of intra-arterial hyperthermia using a dextran-magnetite complex
Mitsumori, M., Hiraoka, M., Shibata, T., Okuno, Y., Masunaga, S.-I., Koishi, M., Okajima, K., Nagata, Y., Nishimura, Y., Abe, M., et al. (1994) · International Journal of Hyperthermia · doi:10.3109/02656739409012371 · Cited by 89
Thermomagnetic surgery for cancer
Rand, R. W., Snow, H. D., Elliott, D. G., & Snyder, M. (1981) · Applied Biochemistry and Biotechnology · doi:10.1007/bf02798277 · Cited by 44
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Neuberger, T., Schöpf, B., Hofmann, H., Hofmann, M., & von Rechenberg, B. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.064 · Cited by 1,728
Functionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
Theranostics: Combining Imaging and Therapy
Kelkar, S. S., & Reineke, T. M. (2011) · Bioconjugate Chemistry · doi:10.1021/bc200151q · Cited by 1,385
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Metadata
- Authors
- Hilger, I., Andrä, W., Hergt, R., Hiergeist, R., Schubert, H., & Kaiser, W. A.
- Venue
- Radiology
- Published
- 2001-02
- Volume
- 218
- Issue
- 2
- Pages
- 570-575
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2163893690
- Cited by
- 224
- References
- 16
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.