Electromagnetic Heating of Breast Tumors in Interventional Radiology: In Vitro and in Vivo Studies in Human Cadavers and Mice
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess relevant parameters for the minimally invasive elimination of breast tumors by using a selective application of magnetite and exposure of the breast to an alternating magnetic field. MATERIALS AND METHODS: The specific absorption rate (SAR) of different magnetite samples was determined calorimetrically. Temperature elevations based on magnetite mass (7-112 mg) and magnetic field amplitude (1.2-6.5 kA/m frequency, 400 kHz) were investigated by using human breast tissue. Parameter combinations (21 mg +/- 9 [SD], 242-second magnetic field exposure, 6.5-kA/m amplitude) were tested in 10 immunodeficient mice bearing human adenocarcinomas (MX-1 cells). Histologic sections of heated tumor tissue were analyzed. RESULTS: SAR data of different magnetite particle types ranged from 3 to 211 W/g. Temperature elevation (DeltaT) as a function of the magnetite mass increased linearly up to 28 mg; at higher masses, a saturation of DeltaT was observed at nearly 88 degrees C. The dependence of DeltaT on magnetic field amplitude (H) revealed a third-order power law: DeltaT = 0.26 degrees C/(kA/m)(3). H(3), with r(2) = 0.95. A mean temperature of 71 degrees C +/- 8 was recorded in the tumor region at the end of magnetic field exposure of the mice. Typical macroscopic findings included tumor shrinkage after heating. Histologically nuclear degenerations were observed in heated malignant cells. CONCLUSION: Magnetic heating of breast tumors is a promising technique for future interventional radiologic treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boring, C. C., Squires, T. S., Tong, T., & Montgomery, S. (1994) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.44.1.7 · Cited by 1,315
Selective Inductive Heating of Lymph Nodes
GILCHRIST, R. K., MEDAL, R., SHOREY, W. D., HANSELMAN, R. C., PARROTT, J. C., & TAYLOR, C. B. (1957) · Annals of Surgery · doi:10.1097/00000658-195710000-00007 · Cited by 1,091
Physical limits of hyperthermia using magnetite fine particles
Hergt, R., Andra, W., d'Ambly, C. G., Hilger, I., Kaiser, W. A., Richter, U., & Schmidt, H.-G. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.718537 · Cited by 658
Self-citationLübbe, A. S., Bergemann, C., Riess, H. B., Schriever, F., Reichardt, P., Possinger, K., Matthias, M., Dörken, B., Herrmann, F., Gürtler, R., et al. (1996) · PubMed · Cited by 652
Usable Frequencies in Hyperthermia with Thermal Seeds
Atkinson, W. J., Brezovich, I. A., & Chakraborty, D. P. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325372 · Cited by 496
Tannock, I. F., Hill, R. P., & Carey, R. W. (1989) · Plastic and Reconstructive surgery · doi:10.1097/00006534-198905000-00037 · Cited by 473
Application of magnetite ferrofluids for hyperthermia
Hiergeist, R., Andrä, W., Buske, N., Hergt, R., Hilger, I., Richter, U., & Kaiser, W. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00145-6 · Cited by 385
Self-citationEffects of Magnetic Fluid Hyperthermia (MFH) on C3H mammary carcinoma in vivo
Jordan, A., Scholz, R., Wust, P., Fähling, H., Krause, J., Wlodarczyk, W., Sander, B., Vogl, T., & Felix, R. (1997) · International Journal of Hyperthermia · doi:10.3109/02656739709023559 · Cited by 325
C.F. Chan, D., B. Kirpotin, D., & A. Bunn, P. (1993) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(93)91113-l · Cited by 319
Gordon, R. T., Hines, J. R., & Gordon, D. (1979) · Medical Hypotheses · doi:10.1016/0306-9877(79)90063-x · Cited by 310
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Neuberger, T., Schöpf, B., Hofmann, H., Hofmann, M., & von Rechenberg, B. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.064 · Cited by 1,728
Functionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
Theranostics: Combining Imaging and Therapy
Kelkar, S. S., & Reineke, T. M. (2011) · Bioconjugate Chemistry · doi:10.1021/bc200151q · Cited by 1,385
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Giri, S., Trewyn, B. G., Stellmaker, M. P., & Lin, V. S. ‐. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200501819 · Cited by 997
Superparamagnetic Colloids: Controlled Synthesis and Niche Applications
Jeong, U., Teng, X., Wang, Y., Yang, H., & Xia, Y. (2007) · Advanced Materials · doi:10.1002/adma.200600674 · Cited by 982
Nanotechnology: Intelligent Design to Treat Complex Disease
Couvreur, P., & Vauthier, C. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-0284-8 · Cited by 948
Ferrite-based magnetic nanofluids used in hyperthermia applications
Sharifi, I., Shokrollahi, H., & Amiri, S. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.10.017 · Cited by 759
Magnetically mediated hyperthermia: current status and future directions
Moroz, P., Jones, S. K., & Gray, B. N. (2002) · International Journal of Hyperthermia · doi:10.1080/02656730110108785 · Cited by 538
Magnetic particle hyperthermia—a promising tumour therapy?
Dutz, S., & Hergt, R. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/45/452001 · Cited by 525
Self-citationDutz, S., & Hergt, R. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.822993 · Cited by 522
Self-citationElectromagnetic activation of shape memory polymer networks containing magnetic nanoparticles
Schmidt, A. M. (2006) · Macromolecular Rapid Communications · doi:10.1002/marc.200600225 · Cited by 518
Targeted temperature sensitive magnetic liposomes for thermo-chemotherapy
Pradhan, P., Giri, J., Rieken, F., Koch, C., Mykhaylyk, O., Döblinger, M., Banerjee, R., Bahadur, D., & Plank, C. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.002 · Cited by 468
Maghemite nanoparticles with very high AC-losses for application in RF-magnetic hyperthermia
Hergt, R., Hiergeist, R., Hilger, I., Kaiser, W. A., Lapatnikov, Y., Margel, S., & Richter, U. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2003.09.001 · Cited by 416
Self-citationMAGNETIC NANOPARTICLE HYPERTHERMIA IN CANCER TREATMENT
GIUSTINI, A. J., PETRYK, A. A., CASSIM, S. M., TATE, J. A., BAKER, I., & HOOPES, P. J. (2010) · Nano LIFE · doi:10.1142/s1793984410000067 · Cited by 390
Magnetic properties of bacterial magnetosomes as potential diagnostic and therapeutic tools
Hergt, R., Hiergeist, R., Zeisberger, M., Schüler, D., Heyen, U., Hilger, I., & Kaiser, W. A. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.047 · Cited by 324
Self-citationIntracellular heating of living cells through Néel relaxation of magnetic nanoparticles
Fortin, J.-P., Gazeau, F., & Wilhelm, C. (2008) · European Biophysics Journal · doi:10.1007/s00249-007-0197-4 · Cited by 322
Effects of size distribution on hysteresis losses of magnetic nanoparticles for hyperthermia
Hergt, R., Dutz, S., & Röder, M. (2008) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/20/38/385214 · Cited by 311
Self-citationAlphandéry, E., Faure, S., Seksek, O., Guyot, F., & Chebbi, I. (2011) · ACS Nano · doi:10.1021/nn201290k · Cited by 307
Biomedical applications of metallic nanoparticles in cancer: Current status and future perspectives
Khursheed, R., Dua, K., Vishwas, S., Gulati, M., Jha, N. K., Aldhafeeri, G. M., Alanazi, F. G., Goh, B. H., Gupta, G., Paudel, K. R., et al. (2022) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2022.112951 · Cited by 286
Biomedical nanoparticle carriers with combined thermal and magnetic responses
Liu, T.-Y., Hu, S.-H., Liu, D.-M., Chen, S.-Y., & Chen, I.-W. (2009) · Nano Today · doi:10.1016/j.nantod.2008.10.011 · Cited by 273
Optimizing Magnetic Nanoparticle Design for Nanothermotherapy
Gazeau, F., Lévy, M., & Wilhelm, C. (2008) · Nanomedicine · doi:10.2217/17435889.3.6.831 · Cited by 258
Intravenous magnetic nanoparticle cancer hyperthermia
Hainfeld, J., & Huang (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s43770 · Cited by 245
“41,52,72 Arterial administration of magnetic microparticles causing emboli in liver tumors followed by AMF heating was found to be vastly superior to direct injection of the same amount and AMF heating to the same temperature.”
Iron Oxide-Based Nanostructures for MRI and Magnetic Hyperthermia
Hilger, I., & Kaiser, W. A. (2012) · Nanomedicine · doi:10.2217/nnm.12.112 · Cited by 243
Self-citationMagnetic nanoparticles for hyperthermia in cancer treatment: an emerging tool
Jose, J., Kumar, R., Harilal, S., Mathew, G. E., Parambi, D. G. T., Prabhu, A., Uddin, M. S., Aleya, L., Kim, H., & Mathew, B. (2020) · Environmental Science and Pollution Research · doi:10.1007/s11356-019-07231-2 · Cited by 234
Salloum, M., Ma, R. H., Weeks, D., & Zhu, L. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730801907937 · Cited by 229
“This approach has been used to treat tumors in liver [7] and breast [7, 8].”
BackgroundMethodThermal Ablation of Tumors Using Magnetic Nanoparticles: An In Vivo Feasibility Study
HILGER, I., HIERGEIST, R., HERGT, R., WINNEFELD, K., SCHUBERT, H., & KAISER, W. A. (2002) · Investigative Radiology · doi:10.1097/00004424-200210000-00008 · Cited by 224
Self-citationComba, S., & Sethi, R. (2009) · Water Research · doi:10.1016/j.watres.2009.05.046 · Cited by 221
Shah, R. R., Davis, T. P., Glover, A. L., Nikles, D. E., & Brazel, C. S. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.03.085 · Cited by 214
“A number of studies have investigated MFH to determine preferred parameters that lead to high SAR values [26-31].”
BackgroundDutz, S., Kettering, M., Hilger, I., Müller, R., & Zeisberger, M. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/26/265102 · Cited by 213
“Tumour volumes were calculated to be between 60 and 110 mm3, as determined by using the formula V = π/6× (product of three principal diameters) (Hilger et al 2001).”
MethodSelf-citationJohannsen, M., Thiesen, B., Jordan, A., Taymoorian, K., Gneveckow, U., Waldöfner, N., Scholz, R., Koch, M., Lein, M., Jung, K., et al. (2005) · The Prostate · doi:10.1002/pros.20213 · Cited by 200
“Other groups have evaluated similar techniques of magnetically mediated hyperthermia using nanoscaled magnetites in animal models of melanoma [21], glioma [22], and breast tumors [23].”
BackgroundPrasad, N. K., Rathinasamy, K., Panda, D., & Bahadur, D. (2007) · Journal of Materials Chemistry · doi:10.1039/b708156a · Cited by 200
de Sousa, M. E., Fernández van Raap, M. B., Rivas, P. C., Mendoza Zélis, P., Girardin, P., Pasquevich, G. A., Alessandrini, J. L., Muraca, D., & Sánchez, F. H. (2013) · The Journal of Physical Chemistry C · doi:10.1021/jp311556b · Cited by 199
Role of dipole-dipole interactions for hyperthermia heating of magnetic nanoparticle ensembles
Haase, C., & Nowak, U. (2012) · Physical Review B · doi:10.1103/physrevb.85.045435 · Cited by 193
Kong, F., Liang, Z., Luan, D., Liu, X., Xu, K., & Tang, B. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01135 · Cited by 188
Buyukhatipoglu, K., & Clyne, A. M. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32972 · Cited by 188
In vivo applications of magnetic nanoparticle hyperthermia
Hilger, I. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.832815 · Cited by 172
“was shown to occur at temperatures higher than 50 C [18].”
BackgroundSelf-citationUse of magnetic nanoparticle heating in the treatment of breast cancer
Hilger, I., Hergt, R., & Kaiser, W. A. (2005) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20055018 · Cited by 170
Self-citationMondal, S., Manivasagan, P., Bharathiraja, S., Santha Moorthy, M., Nguyen, V., Kim, H., Nam, S., Lee, K., & Oh, J. (2017) · Nanomaterials · doi:10.3390/nano7120426 · Cited by 158
“Magnetic thermoablation is another technique that generates the heat by increasing the temperature to 43–55 ◦C with strong toxic effect on cells [9,10].”
BackgroundSchlenk, F., Werner, S., Rabel, M., Jacobs, F., Bergemann, C., Clement, J. H., & Fischer, D. (2017) · Archives of Toxicology · doi:10.1007/s00204-017-1968-z · Cited by 51
Metadata
- Authors
- Hilger, I., Andrä, W., Hergt, R., Hiergeist, R., Schubert, H., & Kaiser, W. A.
- Venue
- Radiology
- Published
- 2001-02
- Volume
- 218
- Issue
- 2
- Pages
- 570-575
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2163893690
- Cited by
- 224
- References
- 16
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.