CoChat

Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction

Nagayama, Yasunori, Oda, Seitaro, Nakaura, Takeshi, Tsuji, Akinori, Urata, Joji, Furusawa, Mitsuhiro, Utsunomiya, Daisuke, Funama, Yoshinori, Kidoh, Masafumi, Yamashita, Yasuyuki · 2018 · RadioGraphics
Cited by 158

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Given the growing awareness of and concern for potential carcinogenic effects of exposure of children to ionizing radiation at CT, optimizing acquisition parameters is crucial to achieve diagnostically acceptable image quality at the lowest possible radiation dose. Among currently available dose reduction techniques, recent technical innovations have allowed the implementation of low tube voltage scans and iterative reconstruction (IR) techniques into daily clinical practice for pediatric CT. The benefits of lowering tube voltage include a considerable reduction in radiation dose and improved contrast on images, especially when an iodinated contrast medium is used. The increase in noise, which is attributed to decreased photon penetration, is a major drawback but is not as severe as that at adult CT because of the small body size of children. In addition, use of IR algorithms can suppress increased noise, yielding wider applicability for low tube voltage scans. However, a careful implementation strategy and methodologic approach are necessary to maximize the potential for dose reduction while preserving diagnostic image quality under each clinical condition. The potential pitfalls of and topics related to these techniques include (a) the effect of tube voltage on the surface radiation dose, (b) the effect of window settings, (c) accentuation of metallic artifacts, (d) deterioration of low contrast detectability at low-dose settings, (e) interscanner variation of x-ray spectra, and (f) a comparison with the use of a spectral shaping technique. Appropriate use of low tube voltage and IR techniques is helpful for radiation dose reduction in most applications of pediatric CT. Online DICOM image stacks are available for this article. ©RSNA, 2018 An earlier incorrect version of this article appeared online. This article was corrected on March 28, 2019.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/rg.2018180041

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Metadata

Authors
Nagayama, Y., Oda, S., Nakaura, T., Tsuji, A., Urata, J., Furusawa, M., Utsunomiya, D., Funama, Y., Kidoh, M., & Yamashita, Y.
Venue
RadioGraphics
Published
2018-09
Volume
38
Issue
5
Pages
1421-1440
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W2890643838
Cited by
158
References
8
FWCI
6.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction. https://app.cochat.ai/papers/10.1148/rg.2018180041
The paper
Nagayama, Y., Oda, S., Nakaura, T., Tsuji, A., Urata, J., Furusawa, M., Utsunomiya, D., Funama, Y., Kidoh, M., & Yamashita, Y. (2018). Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction. RadioGraphics. https://doi.org/10.1148/rg.2018180041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.