Quality Initiatives Respiratory Instructions for CT Examinations of the Lungs: A Hands-on Guide
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In computed tomographic (CT) examinations of the lung, accurate visualization of the natural contrast between the low attenuation of air and the relatively higher attenuation of vessels, airways, and interstitial structures requires cooperative and coordinated respiratory maneuvers by the patient. Inadequate respiratory maneuvers can influence differences in lung attenuation and lead to misinterpretation by (a) increasing attenuation to simulate disease in normal patients, (b) decreasing attenuation to simulate normal contrast in patients with disease, or (c) creating motion artifacts. For respiratory maneuvers to be effective, patients have to be instructed before the examination and coached during it. However, comprehensive descriptions of such instructions and coaching are lacking in the radiology literature. Therefore, respiratory instructions specifically for use in thoracic CT examinations have been devised. Along with patient coaching, use of these instructions can improve image quality. With this hands-on guide, both radiologists and technologists can optimize the respiratory instructions given to their patients and thereby improve the quality of thoracic CT examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Cited by
Diagnosis of Idiopathic Pulmonary Fibrosis. An Official ATS/ERS/JRS/ALAT Clinical Practice Guideline
Raghu, G., Remy-Jardin, M., Myers, J. L., Richeldi, L., Ryerson, C. J., Lederer, D. J., Behr, J., Cottin, V., Danoff, S. K., Morell, F., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201807-1255st · Cited by 4,103
Diagnostic criteria for idiopathic pulmonary fibrosis: a Fleischner Society White Paper
Lynch, D. A., Sverzellati, N., Travis, W. D., Brown, K. K., Colby, T. V., Galvin, J. R., Goldin, J. G., Hansell, D. M., Inoue, Y., Johkoh, T., et al. (2018) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(17)30433-2 · Cited by 1,030
“37 Volumetric CT acquisition is preferred to non-contiguous imaging because it improves the characterisation of patchy disease and delineation of disease extent, clarifies disease distribution, allows identification of ancillary findings, facilitates differentiation between honey-combing and…”
Lynch, D. A., Austin, J. H. M., Hogg, J. C., Grenier, P. A., Kauczor, H.-U., Bankier, A. A., Barr, R. G., Colby, T. V., Galvin, J. R., Gevenois, P. A., et al. (2015) · Radiology · doi:10.1148/radiol.2015141579 · Cited by 658
Self-citationRecommendations for Measuring Pulmonary Nodules at CT: A Statement from the Fleischner Society
Bankier, A. A., MacMahon, H., Goo, J. M., Rubin, G. D., Schaefer-Prokop, C. M., & Naidich, D. P. (2017) · Radiology · doi:10.1148/radiol.2017162894 · Cited by 347
Self-citationDiagnosis of idiopathic pulmonary fibrosis
Choi, H. S. (2021) · Journal of the Korean Medical Association · doi:10.5124/jkma.2021.64.4.248 · Cited by 259
Comparison of Plethysmographic and Helium Dilution Lung Volumes
O'Donnell, C. R., Bankier, A. A., Stiebellehner, L., Reilly, J. J., Brown, R., & Loring, S. H. (2010) · Chest · doi:10.1378/chest.09-1504 · Cited by 87
Self-citation
Metadata
- Authors
- Bankier, A. A., O’Donnell, C. R., & Boiselle, P. M.
- Venue
- RadioGraphics
- Published
- 2008-07
- Volume
- 28
- Issue
- 4
- Pages
- 919-931
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2151271185
- Cited by
- 88
- References
- 1
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.