Diffusion-weighted MR Imaging of Solid and Cystic Lesions of the Pancreas
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Diffusion-weighted magnetic resonance (MR) imaging is increasingly used in the detection and characterization of pancreatic lesions. Diffusion-weighted imaging may provide additional information to radiologists evaluating patients who have cystic or solid neoplasms of the pancreas. Because of greater freedom of motion of water molecules in fluid-rich environments, simple cysts in the pancreas have higher signal intensity on diffusion-weighted images with a b value of 0 sec/mm2 and lower signal intensity on high-b-value images. High apparent diffusion coefficient (ADC) values can be obtained on ADC maps because of the T2 “shine-through” effect. In contrast, solid neoplasms of the pancreas show increased signal intensity relative to the pancreas on diffusion-weighted images with a b value of 0 sec/mm2 and relatively high signal intensity on high-b-value images. Diffusion-weighted imaging can help detect solid pancreatic neoplasms with extremely dense cellularity or extracellular fibrosis by demonstrating significantly low ADC values, and these neoplasms may be better detected on diffusion-weighted MR images because of better contrast, although the resolution is generally worse. However, diffusion-weighted imaging may not be capable of helping definitively characterize solid lesions as inflammatory or neoplastic because of an overlap in ADC values between the two types. For example, it is difficult to distinguish poorly differentiated pancreatic adenocarcinoma from mass-forming pancreatitis at diffusion-weighted imaging because of similarly low ADC values attributed to dense fibrosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Siegel, R., Ward, E., Hao, Y., Xu, J., & Thun, M. J. (2009) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20006 · Cited by 9,709
Moffat, B. A., Chenevert, T. L., Lawrence, T. S., Meyer, C. R., Johnson, T. D., Dong, Q., Tsien, C., Mukherji, S., Quint, D. J., Gebarski, S. S., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501532102 · Cited by 643
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Gass, A., Niendorf, T., & Hirsch, J. G. (2001) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(01)00487-7 · Cited by 178
Magnetic Resonance Imaging of Adenocarcinoma of the Pancreas
Vachiranubhap, B., Kim, Y. H., Balci, N. C., & Semelka, R. C. (2009) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181b48392 · Cited by 83
Cited by
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Imaging diagnosis and staging of pancreatic ductal adenocarcinoma: a comprehensive review
Elbanna, K. Y., Jang, H.-J., & Kim, T. K. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00861-y · Cited by 162
“Nevertheless, it has a limited diagnostic value in differentiating PDAC from mass-forming chronic pancreatitis due to an overlap in ADC values [28, 29].”
Background
Metadata
- Authors
- Wang, Y., Miller, F. H., Chen, Z. E., Merrick, L., Mortele, K. J., Hoff, F. L., Hammond, N. A., Yaghmai, V., & Nikolaidis, P.
- Venue
- RadioGraphics
- Published
- 2011-05
- Volume
- 31
- Issue
- 3
- Pages
- E47-E64
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2030577010
- Cited by
- 175
- References
- 5
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.