Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Sequence-specific MR Imaging Findings That Are Useful in Dating Ischemic Stroke

Allen, Laura M., Hasso, Anton N., Handwerker, Jason, Farid, Hamed·2012·RadioGraphics

Abstract

Patients may present to the hospital at various times after an ischemic stroke. Many present weeks after a neurologic deficit has occurred, as is often the case with elderly patients and those in a nursing home. The ability to determine the age of an ischemic stroke provides useful clinical information for the patient, his or her family, and the medical team. Many times, perfusion imaging is not performed, and pulse sequence-specific magnetic resonance (MR) imaging findings may help determine the age of the infarct. The findings seen at apparent diffusion coefficient mapping and diffusion-weighted, fluid-attenuated inversion recovery (FLAIR) and unenhanced and contrast material-enhanced T1- and T2-weighted gradient-echo and susceptibility-weighted MR imaging may help determine the relative age of a cerebral infarct. Strokes may be classified and dated as early hyperacute, late hyperacute, acute, subacute, or chronic. Recent data indicate that in many patients with restricted diffusion and no change on FLAIR images, it is more likely than was initially thought that the stroke is less than 6 hours old. The time window to administer intravenous tissue plasminogen activator is currently 4.5 hours from the time when the patient was last seen to be normal, and for anterior circulation strokes, the time window for administering intraarterial tissue plasminogen activator is 6 hours from when the patient was last seen to be normal. For this reason, accurate dating is important in patients with ischemic stroke.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/rg.325115760

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 300

Metadata

Authors
Allen, L. M., Hasso, A. N., Handwerker, J., & Farid, H.
Venue
RadioGraphics
Published
2012-09
Volume
32
Issue
5
Pages
1285-1297
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W2127271706
Cited by
300
References
34
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sequence-specific MR Imaging Findings That Are Useful in Dating Ischemic Stroke. https://app.cochat.ai/papers/10.1148/rg.325115760
The paper
Allen, L. M., Hasso, A. N., Handwerker, J., & Farid, H. (2012). Sequence-specific MR Imaging Findings That Are Useful in Dating Ischemic Stroke. RadioGraphics. https://doi.org/10.1148/rg.325115760

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.