Improving Breast Cancer Detection Accuracy of Mammography with the Concurrent Use of an Artificial Intelligence Tool
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Purpose To evaluate the benefits of an artificial intelligence (AI)–based tool for two-dimensional mammography in the breast cancer detection process. Materials and Methods In this multireader, multicase retrospective study, 14 radiologists assessed a dataset of 240 digital mammography images, acquired between 2013 and 2016, using a counterbalance design in which half of the dataset was read without AI and the other half with the help of AI during a first session and vice versa during a second session, which was separated from the first by a washout period. Area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and reading time were assessed as endpoints. Results The average AUC across readers was 0.769 (95% CI: 0.724, 0.814) without AI and 0.797 (95% CI: 0.754, 0.840) with AI. The average difference in AUC was 0.028 (95% CI: 0.002, 0.055, P = .035). Average sensitivity was increased by 0.033 when using AI support (P = .021). Reading time changed dependently to the AI-tool score. For low likelihood of malignancy (< 2.5%), the time was about the same in the first reading session and slightly decreased in the second reading session. For higher likelihood of malignancy, the reading time was on average increased with the use of AI. Conclusion This clinical investigation demonstrated that the concurrent use of this AI tool improved the diagnostic performance of radiologists in the detection of breast cancer without prolonging their workflow. Supplemental material is available for this article. Keywords: Breast, Convolutional Neural Network (CNN), Diagnosis, Mammography © RSNA, 2020
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709 · cited 1×
“Finally, the intraclass correlation coefficient (ICC) was computed to assess the agreement between the 14 radiologists in rating the 240 included cases with and without the use of the AI system (21,22).”
MethodInternational evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287 · cited 3×
“However, apart from the use-case tested (AI tested as a second reader by Kim et al, and AI tested as stand-alone system by McKinney et al), the major difference that emerged with the present study was that mammograms collected in the very same centers used for algorithm training were used during validation, while inde…”
BackgroundResultIdentifying and Avoiding Bias in Research
Pannucci, C. J., & Wilkins, E. G. (2010) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181de24bc · Cited by 1,079 · cited 1×
“…or presenting identifiable features (eg, nipple retraction, invasive cancer larger than approximately 2.5 cm, bilateral cancer, and others to minimize recall bias [15]), and confirming that, for false-negative examinations, malignant lesions were visible and identifiable in retrospect (Fig 1).”
BackgroundInfluentialScreening, T. I. U. P. O. B. C., Marmot, M. G., Altman, D. G., Cameron, D. A., Dewar, J. A., Thompson, S. G., & Wilcox, M. (2013) · British Journal of Cancer · doi:10.1038/bjc.2013.177 · Cited by 1,069 · cited 1×
“B implemented in most developed countries and have been shown to increase earlier stage breast cancer detection leading to improved prognosis and reduced mortality (1).”
BackgroundLarge scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965 · cited 1×
“Preliminary investigations have demonstrated that the use of AI systems as concurrent readers for interpreting mammograms can improve efficiency of the radiologist in terms of time, sensitivity, and specificity (10–14).”
BackgroundIntraclass correlation – A discussion and demonstration of basic features
Liljequist, D., Elfving, B., & Skavberg Roaldsen, K. (2019) · PLOS ONE · doi:10.1371/journal.pone.0219854 · Cited by 905
Park, S. H., & Han, K. (2018) · Radiology · doi:10.1148/radiol.2017171920 · Cited by 894 · cited 1×
“This type of validation is often referred to as external geographic validation and shall be preferred to other types of validation when evaluating generalizability of AI models (28).”
MethodDeep Learning to Improve Breast Cancer Detection on Screening Mammography
Shen, L., Margolies, L. R., Rothstein, J. H., Fluder, E., McBride, R., & Sieh, W. (2019) · Scientific Reports · doi:10.1038/s41598-019-48995-4 · Cited by 873
Deep Neural Networks Improve Radiologists’ Performance in Breast Cancer Screening
Wu, N., Phang, J., Park, J., Shen, Y., Huang, Z., Zorin, M., Jastrzebski, S., Fevry, T., Katsnelson, J., Kim, E., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2945514 · Cited by 689
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678 · cited 1×
“In the United States, computer-aided detection systems are used in 83% of digital mammography examinations (5).”
Method
Cited by
Swanson, K., Wu, E., Zhang, A., Alizadeh, A. A., & Zou, J. (2023) · Cell · doi:10.1016/j.cell.2023.01.035 · Cited by 597
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Heterogeneity and predictors of the effects of AI assistance on radiologists
Yu, F., Moehring, A., Banerjee, O., Salz, T., Agarwal, N., & Rajpurkar, P. (2024) · Nature Medicine · doi:10.1038/s41591-024-02850-w · Cited by 200
Stochastic Dilated Residual Ghost Model for Breast Cancer Detection
Kashyap, R. (2022) · Journal of Digital Imaging · doi:10.1007/s10278-022-00739-z · Cited by 193
“Deep learning has been integrated into a broad variety of models and approaches, resulting in considerable advances in diagnostic and detection procedures [1, 2].”
BackgroundCombining Human Expertise with Artificial Intelligence: Experimental Evidence from Radiology
Agarwal, N., Moehring, A., Rajpurkar, P., & Salz, T. (2023) · doi:10.2139/ssrn.4505053 · Cited by 161
“However, we can test for 12This principle has been used in computer science (Seah et al., 2021; Conant et al., 2019; Pacilè et al., 2020).”
MethodCombining Human Expertise with Artificial Intelligence: Experimental Evidence from Radiology
Agarwal, N., Moehring, A., Rajpurkar, P., & Salz, T. (2023) · doi:10.3386/w31422 · Cited by 161
Metadata
- Authors
- Pacilè, S., Lopez, J., Chone, P., Bertinotti, T., Grouin, J. M., & Fillard, P.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2020-11-01
- Volume
- 2
- Issue
- 6
- Pages
- e190208
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W3097208033
- Cited by
- 161
- References
- 27
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.