The DOI matches its Crossref record.
Neutron Imaging Technique for In Situ Measurement of Water Transport Gradients within Nafion in Polymer Electrolyte Fuel Cells
Open accessAbstract
Water transport is an important consideration in the optimization of polymer electrolyte fuel cell (PEFC) performance, affecting both internal resistance and cathode polarization losses. Novel experiments are described using neutron radiography to measure water gradient profiles within Nafion® in an operating PEFC. Preliminary neutron intensity gradients show qualitative agreement with the expected response of membrane water content to changes in feed gas humidification and fuel cell current. Previous experimental measurements of similar water gradients have generally relied on "integral" measurements such as ac impedance spectroscopy which cannot probe details of the gradient within the membrane. This is one of the first "differential" measurements of water gradients within Nafion. © 1999 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1580822 · Cited by 411
Water Transport Mechanisms in PEMFC Gas Diffusion Layers
Owejan, J. P., Owejan, J. E., Gu, W., Trabold, T. A., Tighe, T. W., & Mathias, M. F. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3468615 · Cited by 204
A phenomenological model of water transport in a proton exchange membrane fuel cell
Janssen, G. J. M. (2001) · Journal of The Electrochemical Society · doi:10.1149/1.1415031 · Cited by 164
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639158 · Cited by 131
Markötter, H., Alink, R., Haußmann, J., Dittmann, K., Arlt, T., Wieder, F., Tötzke, C., Klages, M., Reiter, C., Riesemeier, H., et al. (2012) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2012.01.141 · Cited by 107
Measurement of Water Transport Properties Through Membrane-Electrode Assemblies
Ye, X., & Wang, C.-Y. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2737379 · Cited by 106
Water Transport Across a Polymer Electrolyte Membrane under Thermal Gradients
Fu, R. S., Preston, J. S., Pasaogullari, U., Shiomi, T., Miyazaki, S., Tabuchi, Y., Hussey, D. S., & Jacobson, D. L. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3530794 · Cited by 19
Self-citation
Metadata
- Authors
- Bellows, R. J., Lin, M. Y., Arif, M., Thompson, A. K., & Jacobson, D.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1999-03-01
- Volume
- 146
- Issue
- 3
- Pages
- 1099-1103
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2040339512
- Cited by
- 268
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.