Cited by 106Fuel Cells and Related MaterialsMembrane-based Ion Separation TechniquesAdvancements in Solid Oxide Fuel Cells

Measurement of Water Transport Properties Through Membrane-Electrode Assemblies

Ye, Xinhuai, Wang, Chao-Yang·2007·Journal of The Electrochemical Society

Abstract

A method using a hydrogen pumping cell to measure the electro-osmotic drag (EOD) coefficient of Gore-Select membranes is described. This technique was verified with the measurement of Nafion membranes, yielding results comparable with those reported in the literature and hence supporting its validity for various types of membranes. The EOD coefficient of Gore-Select membranes was measured to be 1.07 over the wide relative humidity range between and 95%. An approach was also proposed to characterize the water concentration at the interface between the membrane and the cathode catalyst layer using high-frequency resistance measurement in an operating fuel cell. Based on the information of water concentrations on both sides of the membrane and the water diffusive flux across the membrane, the water diffusion coefficient of Gore-Select membranes was experimentally determined. It was found that the water diffusion coefficient of Gore-Select membranes is roughly half that of Nafion membranes based on the best fit of our available data in this work.

Integrity signals

Registry

Crossref · 10.1149/1.2737379

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Several later studies have presented evidence that the electroosmotic drag coefficient is constant and very close to unity up to a critical water content associated with the liquid-equilibration phase transition, whereafter it rises linearly.

    “However, several later studies have presented evidence that the electroosmotic drag coefficient is constant and very close to unity up to a critical water content associated with the liquid-equilibration phase transition, whereafter it rises linearly (data tabulated in Table 7) [80,87,103,107]”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ye, X., & Wang, C.-Y.
Affiliations
Pennsylvania State University (US)
Venue
Journal of The Electrochemical Society
Published
2007
Volume
154
Issue
7
Pages
B676
ISSN
0013-4651 (ISSN-L)
OpenAlex
W1812273008
Cited by
106
References
2
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 8 · 2022: 3 · 2021: 4 · 2020: 8 · 2019: 7 · 2018: 4 · 2017: 4 · 2016: 8 · 2015: 2 · 2014: 5 · 2013: 3 · 2012: 4
FWCI
9.77
Type
journal article
Language
en
Open access
closed
Locations
Journal of The Electrochemical Society (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Membrane-based Ion Separation Techniques
  • Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
Keywords
membrane electrode assembly, water transport properties, Nafion membrane, water diffusion coefficient, proton exchange membranes, relative humidity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review