The DOI matches its Crossref record.
Water and Methanol Uptakes in Nafion Membranes and Membrane Effects on Direct Methanol Cell Performance
Abstract
This paper compares direct methanol fuel cells (DMFCs) employing two types of Nafion® (E.I. DuPont de Nemours and Company) membranes of different equivalent weight (EW). Methanol and water uptakes in 1100 and 1200 EW Nafion membranes were determined by weighing and methanol solution‐equilibrated membranes. Both methanol and water uptakes in the 1200 EW membrane were about 70–74% of those in the 1100 EW membrane. The methanol crossover rate corresponding to that in a DMFC at open circuit was measured using a voltammetric method in the DMFC configuration and under the same cell operating conditions. After accounting for the thickness difference between the membrane samples, the methanol crossover rate through a 1200 EW membrane was 52% of that through an 1100 EW membrane. To resolve the cathode and anode performances in an operating DMFC, a dynamic hydrogen electrode was used as a reference electrode. Results show that in an operating DMFC the cathode can be easily flooded, as shown in a DMFC using 1100 EW membrane. An increase in methanol crossover rate decreases the DMFC cathode potential at open circuit. At a high cell current density, the DMFC cathode potential can approach that of a cell. © 2000 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Y., Chen, K. S., Mishler, J., Cho, S. C., & Adroher, X. C. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.09.030 · Cited by 3,329
Anion-exchange membranes in electrochemical energy systems
Varcoe, J. R., Atanassov, P., Dekel, D. R., Herring, A. M., Hickner, M. A., Kohl, P. A., Kucernak, A. R., Mustain, W. E., Nijmeijer, K., Scott, K., et al. (2014) · Energy Environ. Sci. · doi:10.1039/c4ee01303d · Cited by 2,051
Liquid Water Transport in Gas Diffusion Layer of Polymer Electrolyte Fuel Cells
Pasaogullari, U., & Wang, C. Y. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1646148 · Cited by 631
Recent approaches to improve Nafion performance for fuel cell applications: A review
Karimi, M. B., Mohammadi, F., & Hooshyari, K. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2019.09.096 · Cited by 450
Li, X., & Faghri, A. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.10.061 · Cited by 398
Metadata
- Authors
- Ren, X., Springer, T. E., & Gottesfeld, S.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2000
- Volume
- 147
- Issue
- 1
- Pages
- 92
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2023893961
- Cited by
- 401
- References
- 0
- FWCI
- 21.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Water and Methanol Uptakes in Nafion Membranes and Membrane Effects on Direct Methanol Cell Performance. https://app.cochat.ai/papers/10.1149/1.1393161
- The paper
- Ren, X., Springer, T. E., & Gottesfeld, S. (2000). Water and Methanol Uptakes in Nafion Membranes and Membrane Effects on Direct Methanol Cell Performance. Journal of The Electrochemical Society. https://doi.org/10.1149/1.1393161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.