Direct Electrodeposition of Polypyrrole on Aluminum and Aluminum Alloy by Electron Transfer Mediation
The DOI matches its Crossref record.
Abstract
The direct electrodeposition of electroactive conducting polymers on active metals such as iron and aluminum is complicated by the concomitant metal oxidation that occurs at the positive potentials required for polymer formation. In the case of aluminum and its alloys, the oxide layer that forms is an insulator that blocks electron transfer and impedes polymer formation and deposition. As a result, only patchy nonuniform polymer films are obtained. Electron transfer mediation is a well-known technique for overcoming kinetic limitations of electron transfer at metal electrodes. In this work, we report the use of electron transfer mediation for the direct electrodeposition of polypyrrole onto aluminum and onto Al 2024-T3 alloy. This report focuses on the use of Tiron (4,5-dihydroxy-1,3-benzenedisulfonic acid disodium salt) as the mediator, although catechol appears to function in a similar manner. Depositions were carried out under galvanostatic conditions at current densities of 1 mA / cm 2 . The mediator reduced the deposition potential by nearly 500 mV compared to deposition performed in the absence of mediator (where Tiron was replaced by p -toluene sulfonic acid sodium salt). Polypyrrole formation and deposition appears to occur with 100% current efficiency and uniform films are obtained. Results of the characterization of these films by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, conductivity measurements, and adhesion measurements are presented. © 2002 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Self-citationConducting Polymer Nanomaterials and Their Applications
Jang, J. (2006) · Advances in Polymer Science · doi:10.1007/12_075 · Cited by 425
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Lignin-derivatives based polymers, blends and composites: A review
Naseem, A., Tabasum, S., Zia, K. M., Zuber, M., Ali, M., & Noreen, A. (2016) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2016.08.030 · Cited by 343
Substrate dependent stability of conducting polymer coatings on medical electrodes
Green, R. A., Hassarati, R. T., Bouchinet, L., Lee, C. S., Cheong, G. L. M., Yu, J. F., Dodds, C. W., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.017 · Cited by 205
Metadata
- Authors
- Tallman, D. E., Vang, C., Wallace, G. G., & Bierwagen, G. P.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2002
- Volume
- 149
- Issue
- 3
- Pages
- C173
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W1598079440
- Cited by
- 140
- References
- 0
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct Electrodeposition of Polypyrrole on Aluminum and Aluminum Alloy by Electron Transfer Mediation. https://app.cochat.ai/papers/10.1149/1.1448820
- The paper
- Tallman, D. E., Vang, C., Wallace, G. G., & Bierwagen, G. P. (2002). Direct Electrodeposition of Polypyrrole on Aluminum and Aluminum Alloy by Electron Transfer Mediation. Journal of The Electrochemical Society. https://doi.org/10.1149/1.1448820
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.