The DOI matches its Crossref record; the references it cites are not checked yet.
A Materials Roadmap to Functional Neural Interface Design
Open accessAbstract
Advancements in neurotechnologies for electrophysiology, neurochemical sensing, neuromodulation, and optogenetics are revolutionizing scientific understanding of the brain while enabling treatments and preventative measures for a variety of neurological disorders. The grand challenge in neural interface engineering is to seamlessly integrate the interface between neurobiology and engineered technology to record from and modulate neurons over chronic timescales. However, the biological inflammatory response to implants, neural degeneration, and long‐term material stability diminishes the quality of the interface overtime. Recent advances in functional materials are aimed at engineering solutions for chronic neural interfaces, yet, the development and deployment of neural interfaces designed from novel materials have introduced new challenges that have been largely unaddressed. Many engineering efforts that solely focus on optimizing individual probe design parameters, such as softness or flexibility, downplay critical multidimensional interactions between different physical properties of the device that contribute to overall performance and biocompatibility. Moreover, the use of these new materials present substantial new difficulties that must be addressed before regulatory approval for use in human patients is achievable. In this review, the interdependence of different electrode components is highlighted to demonstrate the current material‐based challenges facing the field of neural interface engineering.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Biocompatibility is the determining factor for the safety and stability of implants in long-term chronic operation (see section 2).[304]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [304]
In the citing paper
“For this reason, non-penetrating cortical surface microelectrodes represent a potentially attractive alternative and form the basis of the system described here 53,63 .”
From The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform (2022) · cites this paper as [53]
In the citing paper
“Recently developed thin-film µECoG arrays have demonstrated the ability to conform to the brain surface safely for several months while reliably recording multi-unit and single-unit activity in certain anatomic settings 53,57 .”
From The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform (2022) · cites this paper as [53]
Citations
The citation lists are queued
They are fetched later and appear here then.
References 514 · Cited by 389
Research works printed but not linked: 80
- Woldring S., 1950, Acta Physiol. Pharmacol. Neerl., 1, 369
- Aregueta‐Robles U. A., 2015, Front. Neuroeng., 7, 57
- 10.1038/nmat3468 · DOI · Paper page
- Obien M. E. J., 2014, Front. Neurosci., 8, 423
- 10.1088/1741-2560/8/4/046016 · DOI · Paper page
- 10.1088/1741-2560/9/5/056015 · DOI · Paper page
- 10.1038/nmat3468 · DOI · Paper page
- Lahann J., 2005, Abstr. Pap. Am. Chem. Soc., 230, U4292
- Lahann J., 2005, Abstr. Pap. Am. Chem. Soc., 229, U1106
- 10.1002/1521-3773(20010817)40:16<2947::AID-ANIE22222947>3.0.CO;2-4 · doi:10.1002/1521-3773(20010817)40:16<2947::aid-anie22222947>3.0.co;2-4
- 10.1002/1521-3773(20010903)40:17<3166::AID-ANIE3166>3.0.CO;2-# · doi:10.1002/1521-3773(20010903)40:17<3166::aid-anie3166>3.0.co;2-#
- Cogan S. F., 2004, Engineering in Medicine and Biology
- 10.1109/TBME.2002.805487 · DOI · Paper page
- Gaylor J. M., 2013, JAMA Otolaryngol., 139, 265
- 10.1039/C5TB00108K · DOI
- Negi S., 2012, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2012, 5142
- 10.1016/S0142-9612(02)00415-5 · DOI · Paper page
- 10.1016/0165-0270(83)90062-6 · DOI
- 10.1016/j.jneumeth.2011.03.012 · DOI · Paper page
- Pudenz R. H., 1942, Surgery, 12, 791
- Desai S. A., 2010, Front. Neuroeng., 3, 5
- Heim M., 2012, J. Physiol., 106, 137
- 10.1016/j.biomaterials.2012.05.017 · DOI · Paper page
- 10.1016/j.biomaterials.2012.05.017 · DOI · Paper page
- Kozai T. D. Y., 2014, Nanotechnology and Neuroscience: Nano‐Electronic, Photonic and Mechanical Neuronal Interfacing, 71, 10.1007/978-1-4899-8038-0_4 · DOI
- 10.1007/BF02364479 · DOI · Paper page
- 10.1109/TNSRE.2007.909811 · DOI · Paper page
- 10.1109/TBME.2015.2445713 · DOI · Paper page
- 10.1016/S0013-4686(99)00121-8 · DOI · Paper page
- 10.1038/nmat3468 · DOI · Paper page
- 10.1088/1741-2560/7/4/046011 · DOI · Paper page
- 10.1088/1741-2560/6/5/056003 · DOI · Paper page
- Baumbach G. L., 1989, Am. J. Physiol., 256, H493
- 10.1016/j.biomaterials.2014.10.040 · DOI · Paper page
- 10.1088/1741-2560/3/3/001 · DOI · Paper page
- Gilgunn P. J., 2012, presented at 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS)
- Sohal H. S., 2015, Front. Neuroeng.
- Subbaroyan J., 2007, Investigations of Tethering Induced Injury Response in Brain Tissue by Intracortical Implants through Modeling and In Vivo Experiments
- Fiedler E., 2014, Engineering in Medicine and Biology Society
- Loffler S., 2012, Biomed. Technol., 57, 104
- Hassler C., 2009, 4th European Conf. of the Int. Federation for Medical and Biological Engineering, 2439
- Kisban S., 2007, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2007, 175
- Morrison B., 2003, Stapp Car Crash J., 47, 93
- 10.1088/1741-2560/3/3/002 · DOI · Paper page
- Haj Hosseini N., 2007, 2007 29th Ann. Int. Conf. of the IEEE Engineering in Medicine and Biology Society, 4711
- 10.1016/S0006-8993(03)03023-3 · DOI · Paper page
- 10.1088/1741-2560/2/4/003 · DOI · Paper page
- 10.1088/1741-2560/2/4/006 · DOI · Paper page
- 10.1088/1741-2560/8/4/046010 · DOI
- 10.1016/j.jneumeth.2009.08.002 · DOI · Paper page
- 10.1016/j.biomaterials.2014.07.039 · DOI · Paper page
- 10.1088/1741-2560/12/4/046009 · DOI · Paper page
- 10.1016/j.biomaterials.2014.07.039 · DOI · Paper page
- 10.1088/1741-2560/10/4/046016 · DOI · Paper page
- 10.1038/nmat3468 · DOI · Paper page
- Reddy J. D., 2008, Mater. Res. Soc. Symp. Proc.
- 10.1088/1741-2560/10/6/066014 · DOI · Paper page
- Erdogan O., 2002, Indian Pacing Electrophysiol. J., 2, 74
- Abdo A., 2009, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, 626
- Garg A., 2010, Parkinson's Dis., 2010, 189371
- Fernández F. S., 2010, Parkinson's Dis., 2010, 409356
- Larson P. J., 2011, presented at 5th International IEEE/EMBS Conference on Neural Engineering (NER)
- Abdo A., 2011, IEEE Trans. Biomed. Circuits Syst., 2011, 1
- Wang Y., 2016, Front. Neurosci., 10, 69
- Freedman M. S., 2014, Phys. Chem. Commun., 1, 15
- 10.1002/(SICI)1097-4636(199908)46:2<150::AID-JBM3>3.0.CO;2-T · doi:10.1002/(sici)1097-4636(199908)46:2<150::aid-jbm3>3.0.co;2-t
- 10.1016/j.jneumeth.2011.03.012 · DOI · Paper page
- 10.3389/fneng.2014.00002 · DOI · Paper page
- Lind G., 2013, Sci. Rep., 3, 11830
- 10.1109/TBME.2004.827465 · DOI
- 10.1016/j.biomaterials.2011.04.051 · DOI · Paper page
- 10.1016/j.biomaterials.2016.02.013 · DOI
- 10.1088/1741-2560/12/1/016008 · DOI · Paper page
- Schwaerzle M., 2015, presented at 18th International Conference on Solid‐State Sensors, Actuators, and Microsystems (Transducers)
- Borreman A., 2002, IEEE/LEOS Benelux Chapter 2002 Annual Symposium
- Son Y., 2015, presented at 28th IEEE International Conference on Micro Electro Mechanical Systems (MEMS)
- Han T., 2008, presented at Conference on Optoelectronic and Microelectronic Materials and Devices (COMMAD)
- Im M., 2011, presented at IEEE 24th International Conference on Micro Electro Mechanical Systems (MEMS)
- Yang Y., 2008, Appl. Phys. Lett., 92, 150
- Khurram A., 2013, presented at Engineering in Medicine and Biology Society (EMBC)
Metadata
- Authors
- Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y.
- Affiliations
- University of Pittsburgh (US)
- Department of Neurologic Surgery 200 First St. SW Rochester MN 55905 USA
- Electrical and Computer Engineering 1301 Beal Ave., 2227 EECS Ann Arbor MI 48109 USA
- Corresponding author
- Kozai, Takashi D. Y.
- ORCID
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-07-19
- Volume
- 28
- Issue
- 12
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- PMC
- PMC5963731
- OpenAlex
- W2737445139
- Semantic Scholar
- bd746195b50bb60944c9fbaf1c859bc08c642634
- Cited by
- 389
- References
- 514
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 40 · 2023: 50 · 2022: 42 · 2021: 62 · 2020: 48 · 2019: 32 · 2018: 28 · 2017: 5
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Advanced Functional Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (1R01NS094396, U01‐NS090526‐01, R01‐NS094404)
- Grainger Foundation
- National Science Foundation (1545858)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, chronic neural recording, biocompatibility, neuroinflammation, neurodegeneration, electrode flexibility, neuromodulation, optogenetics, neurochemical sensing, regulatory approval
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Materials Roadmap to Functional Neural Interface Design. https://app.cochat.ai/papers/10.1002/adfm.201701269
- The paper
- Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018). A Materials Roadmap to Functional Neural Interface Design. Advanced Functional Materials. https://doi.org/10.1002/adfm.201701269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.