The DOI matches its Crossref record.
Determination of Improved Selectivity Coefficients of Polymer Membrane Ion‐Selective Electrodes by Conditioning with a Discriminated Ion
Abstract
A new method for determining selectivity coefficients of carrier based ion‐selective electrodes toward highly discriminated ions is proposed. For each separately measured ion solution, the interfacial layer of the membrane contacting the sample must contain only the ion to be measured for the experimental determination of Nikolskii coefficients that reflect the true ion‐exchange selectivity of the membrane. For this reason, it is recommended here that the electrode membrane is conditioned in a solution of a discriminated ion that, preferably, is equal to the cation of the tetraphenylborate salt incorporated in the membrane. The selectivity of valinomycin based plasticized poly(vinyl chloride) membrane electrodes has been characterized by using this new method and logarithmic Nikolskii coefficients for K + over Na + , Mg 2 + , and Ca 2 + have been determined as −4.5, −7.5, and −6.9, respectively. All measured ions showed near‐Nernstian electrode slopes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Self-citationEyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Hassan, S. S. M., & Fathy, M. A. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06494-y · Cited by 18
Metadata
- Authors
- Bakker, E.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1996-04-01
- Volume
- 143
- Issue
- 4
- Pages
- L83-L85
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2082720682
- Cited by
- 205
- References
- 0
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Improved Selectivity Coefficients of Polymer Membrane Ion‐Selective Electrodes by Conditioning with a Discriminated Ion. https://app.cochat.ai/papers/10.1149/1.1836608
- The paper
- Bakker, E. (1996). Determination of Improved Selectivity Coefficients of Polymer Membrane Ion‐Selective Electrodes by Conditioning with a Discriminated Ion. Journal of The Electrochemical Society. https://doi.org/10.1149/1.1836608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.