Eyeglasses based wireless electrolyte and metabolite sensor platform
Open accessAbstract
We presented the first example of a fully integrated eyeglasses wireless multiplexed chemical sensing platform capable of simultaneous real-time monitoring of sweat electrolytes and metabolites.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several research groups have recently developed mechanically flexible and fully integrated wearable sweat sensors for analysis of biofluid metabolites and electrolytes and pH sensing.
“Several research groups have recently developed mechanically flexible and fully integrated wearable sweat sensors (in wristband, temporary tattoo, eyeglasses, mouthguard) for analysis of biofluid metabolites and electrolytes (e.g., glucose, lactate, sodium, potassium) and pH sensing [156-160].”
From Wearables and the Medical Revolution (2018) · cites this paper as [158]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · see citing works
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · see citing works
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462 · see citing works
Wang, X., Gu, Y., Xiong, Z., Cui, Z., & Zhang, T. (2013) · Advanced Materials · doi:10.1002/adma.201304248 · Cited by 1,403 · see citing works
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401 · see citing works
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308 · see citing works
Choong, C., Shim, M., Lee, B., Jeon, S., Ko, D., Kang, T., Bae, J., Lee, S. H., Byun, K., Im, J., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305182 · Cited by 1,249 · see citing works
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · see citing works
Self-citationLong, G. L., Voigtman, E., Kosinski, M. A., et al. (1983) · Analytical Chemistry · doi:10.1021/ac00259a060 · Cited by 1,121 · see citing works
Umezawa, Y., Bühlmann, P., Umezawa, K., Tohda, K., & Amemiya, S. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072101851 · Cited by 1,102 · see citing works
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870 · see citing works
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862 · see citing works
Self-citationImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861 · see citing works
Self-citationWang, J. (2006) · Wiley eBooks · doi:10.1002/0471790303 · Cited by 848 · see citing works
Self-citationSensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781 · see citing works
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · see citing works
Self-citationSonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724 · see citing works
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700 · see citing works
Self-citationWearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678 · see citing works
Self-citationNoninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599 · see citing works
Self-citationCorrelation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570 · see citing works
Gennari, F. J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390707 · Cited by 565 · see citing works
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490 · see citing works
Self-citationTattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379 · see citing works
Self-citationNon-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367 · see citing works
Self-citationSmart bandage with wireless connectivity for uric acid biosensing as an indicator of wound status
Kassal, P., Kim, J., Kumar, R., de Araujo, W. R., Steinberg, I. M., Steinberg, M. D., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2015.03.018 · Cited by 319 · see citing works
Self-citationTattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 316 · see citing works
Self-citationBandage‐Based Wearable Potentiometric Sensor for Monitoring Wound pH
Guinovart, T., Valdés‐Ramírez, G., Windmiller, J. R., Andrade, F. J., & Wang, J. (2014) · Electroanalysis · doi:10.1002/elan.201300558 · Cited by 308 · see citing works
Self-citationFormulation and stability of a novel artificial human sweat under conditions of storage and use
Harvey, C. J., LeBouf, R. F., & Stefaniak, A. B. (2010) · Toxicology in Vitro · doi:10.1016/j.tiv.2010.06.016 · Cited by 275 · see citing works
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269 · see citing works
Self-citationGoogle Glass in pediatric surgery: An exploratory study
Muensterer, O. J., Lacher, M., Zoeller, C., Bronstein, M. E., & Kübler, J. F. (2014) · International Journal of Surgery · doi:10.1016/j.ijsu.2014.02.003 · Cited by 249 · see citing works
Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes
Guinovart, T., Parrilla, M., Crespo, G. A., Rius, F. X., & Andrade, F. J. (2013) · The Analyst · doi:10.1039/c3an00710c · Cited by 209 · see citing works
Bakker, E. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836608 · Cited by 205 · see citing works
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, S., Lonjaret, T., Crisp, D. N., Badier, J., Malliaras, G. G., & Ismailova, E. (2015) · Scientific Reports · doi:10.1038/srep15003 · Cited by 195 · see citing works
Fluid and electrolyte loss and replacement in exercise
Maughan, R. J. (1991) · Journal of Sports Sciences · doi:10.1080/02640419108729870 · Cited by 191 · see citing works
Sodium ion concentration vs. sweat rate relationship in humans
Buono, M. J., Ball, K. D., & Kolkhorst, F. W. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00015.2007 · Cited by 186 · see citing works
Wearable textile biofuel cells for powering electronics
Jia, W., Wang, X., Imani, S., Bandodkar, A. J., Ramírez, J., Mercier, P. P., & Wang, J. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta04796f · Cited by 184 · see citing works
Self-citationPankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135 · see citing works
Biomedical Perspective of Electrochemical Nanobiosensor
Singh, P., Pandey, S. K., Singh, J., Srivastava, S., Sachan, S., & Singh, S. K. (2015) · Nano-Micro Letters · doi:10.1007/s40820-015-0077-x · Cited by 133 · see citing works
Factors influencing the restoration of fluid and electrolyte balance after exercise in the heat.
Maughan, R., Leiper, J. B., & Shirreffs, S. M. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.3.175 · Cited by 122 · see citing works
Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat
Parrilla, M., Ferré, J. F., Guinovart, T., & Andrade, F. J. (2016) · Electroanalysis · doi:10.1002/elan.201600070 · Cited by 122 · see citing works
A Wireless Pressure Sensor Integrated with a Biodegradable Polymer Stent for Biomedical Applications
Park, J., Kim, J.-K., Patil, S. J., Park, J., Park, S., & Lee, D. (2016) · Sensors · doi:10.3390/s16060809 · Cited by 104 · see citing works
Recovery from prolonged exercise: Restoration of water and electrolyte balance
Maughan, R. J., & Shirreffs, S. M. (1997) · Journal of Sports Sciences · doi:10.1080/026404197367308 · Cited by 92 · see citing works
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71 · see citing works
Doctors among early adopters of Google Glass
Glauser, W. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.109-4607 · Cited by 70 · see citing works
Comparison of sweat rate during graded exercise and the local rate induced by pilocarpine
Vimieiro-Gomes, A. C., Magalhães, F. C., Amorim, F. T., Machado-Moreira, C. A., Rosa, M. S., Lima, N. R. V., & Rodrigues, L. O. C. (2005) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2005000700017 · Cited by 49 · see citing works
Sweat analysis following pressure ischaemia in a group of debilitated subjects.
Polliack, A. A., Taylor, R. P., & Bader, D. L. (1997) · PubMed · Cited by 41 · see citing works
Google Glass-Directed Monitoring and Control of Microfluidic Biosensors and Actuators
Zhang, Y. S., Busignani, F., Ribas, J., Aleman, J., Rodrigues, T. N., Shaegh, S. A. M., Massa, S., Rossi, C. B., Taurino, I., Shin, S.-R., et al. (2016) · Scientific Reports · doi:10.1038/srep22237 · Cited by 40 · see citing works
Electrolyte Loss in Sweat and Iodine Deficiency in a Hot Environment
Mao, I., Chen, M.-L., & Ko, Y.-C. (2001) · Archives of Environmental Health An International Journal · doi:10.1080/00039890109604453 · Cited by 38 · see citing works
Secretion of eccrine sweat glands during exercise.
Pilardeau, P., Vaysse, J., Garnier, M., Joublin, M., & Valeri, L. (1979) · British Journal of Sports Medicine · doi:10.1136/bjsm.13.3.118 · Cited by 32 · see citing works
Effect of different work-loads on sweat production and composition in man.
Pilardeau, P., Lavie, F., Vaysse, J., Garnier, M., Harichaux, P., Jn, M., & Chalumeau, M. T. (1988) · PubMed · Cited by 16 · see citing works
Flagged first, then by citations
Research works printed but not linked: 6
- [2]Mukhopadhyay SC IEEE Sens J 2015 15 1321 1330
- [25]Kim J Imani S De Araujo WR Warchall J Valdés-Ramírez G Paixão TRLC Mercier PP Wang J Biosens Bioelectron 2015 74 1061 1068 26276541 PMC4718709
- [35]Pilardeau PA Lavie F Vaysse J Garnier M Harichaux P Margo JN Chalumeau MT J Sports Med Phys Fitness 1988 28 247 52 3230906
- [36]Polliack A Taylor R Bader D J Rehabil Res Dev 1997 34 303 8 9239623
- [52]Gao W Emaminejad S Nyein HYY Challa S Chen K Peck A Fahad HM Ota H Shiraki H Kiriya D Lien DH Brooks GA Davis RW Javey A Nature 2016 529 509 514 26819044 PMC4996079
- [53]Bandodkar AJ Molinnus D Mirza O Guinovart T Windmiller JR Valdés-Ramírez G Andrade FJ Schöning MJ Wang J Biosens Bioelectron 2014 54 603 609 24333582
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Self-citationYang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641 · see citing works
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350 · see citing works
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · see citing works
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654 · see citing works
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564 · see citing works
From pre-diabetes to diabetes: diagnosis, treatments and translational research
Khan, R., Chua, Z., Tan, J., Yang, Y., Liao, Z., & Zhao, Y. (2019) · Medicina · doi:10.3390/medicina55090546 · Cited by 484 · see citing works
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475 · see citing works
Self-citationWearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442 · see citing works
Self-citationEyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315 · see citing works
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237 · see citing works
Self-citationRecent advances in noninvasive flexible and wearable wireless biosensors
Salim, A., & Lim, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111422 · Cited by 153 · see citing works
Designing wearable microgrids: towards autonomous sustainable on-body energy management
Yin, L., Kim, K. N., Trifonov, A., Podhajny, T., & Wang, J. (2022) · Energy & Environmental Science · doi:10.1039/d1ee03113a · Cited by 111 · see citing works
Self-citationLi, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119 · see citing works
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112 · see citing works
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86 · see citing works
Hong, W., & Lee, W. G. (2020) · The Analyst · doi:10.1039/d0an01484b · Cited by 47 · see citing works
- Authors
- Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J.
- Affiliations
- University of California System (US)
- Corresponding author
- Wang, Joseph
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 17
- Issue
- 10
- Pages
- 1834-1842
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC5507201
- OpenAlex
- W2608999297
- Cited by
- 311
- References
- 51
- Citations by year
- 2026: 15 · 2025: 36 · 2024: 40 · 2023: 37 · 2022: 33 · 2021: 46 · 2020: 47 · 2019: 30 · 2018: 17 · 2017: 8 · 2015: 1
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (R21EB019698)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Keywords
- spectacle, wearable sensors, sweat electrolytes, lactate biosensor, potassium ion-selective electrode, wireless sensor platform, Bluetooth data transmission, screen-printed sensors, sweat glucose monitoring, real-time physiological monitoring
- MeSH terms
- Electrolytes, Equipment Design, Eyeglasses, Female, Humans, Male, Monitoring, Physiologic, Potentiometry, Sweat, Biosensing Techniques, Lactic Acid, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review