Analysis of Polarization Curves to Evaluate Polarization Sources in Hydrogen/Air PEM Fuel Cells
Open accessThe DOI matches its Crossref record.
Abstract
A step-by-step technique to evaluate six sources of polarization, mainly associated with the cathode, in hydrogen/air proton exchange membrane fuel cells is demonstrated. The six sources of polarization were nonelectrode ohmic overpotential, electrode ohmic overpotential, nonelectrode concentration overpotential, electrode concentration overpotential, activation overpotential from the Tafel slope, and activation overpotential from catalyst activity. The technique is demonstrated as applied in the analysis of hydrogen/air polarization curves of an in-house membrane electrode assembly (MEA) using hydrogen/oxygen polarization curves as a diagnostic tool. The analysis results are discussed at three cell temperature/relative humidity (RH)/oxygen partial pressure atm) conditions at atmospheric pressure: and which represent a near fully-humidified, a moderately humidified, and a low humidified condition, respectively. At the higher temperature operating conditions the RH and decrease resulting in higher electrode ohmic resistance (0.020, 0.020, and 0.035 Ω cm 2 , respectively), lower limiting current (2019, 1314, and 819 mA/cm 2 , respectively), and lower onset current density for significant electrode concentration overpotential (80, 60, and 40 mA/cm 2 , respectively). The technique is useful for diagnosing the main sources of loss in MEA development work, especially for high temperature/low relative humidity operation where several sources of loss are present simultaneously. © 2005 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scientific Aspects of Polymer Electrolyte Fuel Cell Durability and Degradation
Borup, R., Meyers, J., Pivovar, B., Kim, Y. S., Mukundan, R., Garland, N., Myers, D., Wilson, M., Garzon, F., Wood, D., et al. (2007) · Chemical Reviews · doi:10.1021/cr050182l · Cited by 3,402
Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques
WU, J., YUAN, X., WANG, H., BLANCO, M., MARTIN, J., & ZHANG, J. (2008) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.01.013 · Cited by 380
Yousfi-Steiner, N., Moçotéguy, P., Candusso, D., Hissel, D., Hernandez, A., & Aslanides, A. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.04.037 · Cited by 357
Jeon, S., Lee, J., Rios, G. M., Kim, H.-J., Lee, S.-Y., Cho, E., Lim, T.-H., & Hyun Jang, J. (2010) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2010.06.044 · Cited by 113
Aizawa, M., Gyoten, H., Salah, A., & Liu, X. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3502613 · Cited by 52
Sambandam, S., & Ramani, V. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b921916a · Cited by 49
Swelling agent adopted decal transfer method for membrane electrode assembly fabrication
Cho, D. H., Lee, S. Y., Shin, D. W., Hwang, D. S., & Lee, Y. M. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.02.037 · Cited by 15
Metadata
- Authors
- Williams, M. V., Kunz, H. R., & Fenton, J. M.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2005
- Volume
- 152
- Issue
- 3
- Pages
- A635
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2128088324
- Cited by
- 125
- References
- 0
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.