Transport Limited Currents Close to an Ultrasonic Horn
Open accessThe DOI matches its Crossref record.
Abstract
The effect of changing the distance of an ultrasonic horn tip from a stationary platinum disk electrode on limiting current density at various electroanalyte concentrations, ultrasonic frequencies (20 and ), and ultrasonic intensities was studied in an attempt to find the optimum position required for maximum sonoelectrochemical effect in "face-on" mode. Our findings were compared to mathematical models available in the literature, for the mass transport of electroactive species to the electrode under hydrodynamic flow conditions normal to the ultrasonic horn. A good fit with experimental results was found and confirmed the dependence of limiting current to operating parameters such as ultrasonic power, electrode-to-horn distances and electroactive species diffusion coefficient, and also highlighting the importance of ultrasonic frequency. From mass balance equations, it was then possible to develop an approach by analogy to an electrode subjected to pure hydrodynamic flow. A Levich-like equation relating the limiting current density, the square root of ultrasonic intensity, and the inverse square root of the electrode-horn distance was generated for ultrasonic frequencies of 20 and , allowing the generation of an "equivalent" flow velocity under sonication, an important and useful parameter in chemical engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The importance of ultrasonic parameters in the preparation of fuel cell catalyst inks
Pollet, B. G., & Goh, J. T. E. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2013.09.160 · Cited by 117
Self-citationLet’s Not Ignore the Ultrasonic Effects on the Preparation of Fuel Cell Materials
Pollet, B. G. (2014) · Electrocatalysis · doi:10.1007/s12678-014-0211-4 · Cited by 70
Self-citationZhu, F., Liu, Z., Wu, X., Xu, D., Li, Q., Chen, X., Pang, W., Duan, X., & Wang, Y. (2023) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2023.106618 · Cited by 7
Metadata
- Authors
- Pollet, B. G., Hihn, J.-Y., Doche, M.-L., Lorimer, J. P., Mandroyan, A., & Mason, T. J.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2007
- Volume
- 154
- Issue
- 10
- Pages
- E131
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W1596876251
- Cited by
- 65
- References
- 0
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transport Limited Currents Close to an Ultrasonic Horn. https://app.cochat.ai/papers/10.1149/1.2766645
- The paper
- Pollet, B. G., Hihn, J.-Y., Doche, M.-L., Lorimer, J. P., Mandroyan, A., & Mason, T. J. (2007). Transport Limited Currents Close to an Ultrasonic Horn. Journal of The Electrochemical Society. https://doi.org/10.1149/1.2766645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.