Performance of Nano Structured Thin Film (NSTF) Electrodes under Partially-Humidified Conditions
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
3M's Nano Structured Thin Film (NSTF) electrode, being a core-shell catalyst, offers a novel mean to enhance the performance and lower Pt cost in a polymer electrolyte fuel cell (PEFC). In the present work, fuel cell performance of NSTF is reported and the underlying physics dictating NSTF behavior is probed. It was found that NSTF with 0.15 mg Pt /cm 2 Pt loading shows comparable performance to that of a conventional Pt/C electrode with 0.4 mg Pt /cm 2 loading in a highly humidified condition at 80°C. However, the NSTF performs poorly under dry conditions. A single-phase model was developed to elucidate the underlying phenomenon governing NSTF performance under partially-humidified conditions. NSTF proton conductivity as a function of relative humidity (RH) was determined and the model predictions were compared against a range of experimental data. Detailed results suggest that poor NSTF performance under dry operation is due to low proton conductivity over Pt surface, which reduces catalyst utilization. The importance of water management is highlighted to improve NSTF performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion of Water in Nafion 115 Membranes
Motupally, S., Becker, A. J., & Weidner, J. W. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1393879 · Cited by 478
Quasi-3D modeling of water transport in polymer electrolyte fuel cells
Kulikovsky, A. A. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1611489 · Cited by 171
Cited by
Kongkanand, A., & Mathias, M. F. (2016) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.6b00216 · Cited by 1,202
Self-citationUnderstanding the electrocatalysis of oxygen reduction on platinum and its alloys
Stephens, I. E. L., Bondarenko, A. S., Grønbjerg, U., Rossmeisl, J., & Chorkendorff, I. (2012) · Energy & Environmental Science · doi:10.1039/c2ee03590a · Cited by 1,176
Kodama, K., Motobayashi, K., Shinohara, A., Hasegawa, N., Kudo, K., Jinnouchi, R., Osawa, M., & Morimoto, Y. (2018) · ACS Catalysis · doi:10.1021/acscatal.7b03571 · Cited by 258
Debe, M. K. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.049306jes · Cited by 183
Zamel, N. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.01.091 · Cited by 93
Metadata
- Authors
- Sinha, P. K., Gu, W., Kongkanand, A., & Thompson, E.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2011
- Volume
- 158
- Issue
- 7
- Pages
- B831
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2023658832
- Cited by
- 74
- References
- 2
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.