Cited by 7Gas Sensing Nanomaterials and SensorsElectrochemical sensors and biosensorsCatalytic Processes in Materials Science

Cubic Bi 2 O 3 -Based Electrochemical Nitric Oxide Sensor Using Double Perovskite Oxide Electrodes

Bhardwaj, Aman, Bae, Hohan, Mathur, Lakshya, Mathur, Sanjay, Song, Sun-Ju·2022·Journal of The Electrochemical Society

Abstract

For achieving a sustainable energy future, energy consumption through renewable sources needs to be maximized and greenhouse emissions should be radically reduced. Automotive exhausts sharing the largest global NO X emissions must meet regulated standards by after-treatment systems (ATS) equipped with smart electronic feedback loops through on-board NO X monitoring. Herein, we demonstrate an efficient (Dy, W) co-doped Bi 2 O 3 -based electrochemical sensing architecture equipped with Ln 2 NiMnO 6 double perovskite oxides (DPOs) as electrode materials for selective nitric oxides (NO) detection. The sensor configuration facilitates operation in a wide temperature range (325 °C–500 °C) with high sensitivity of 50 mV/decade, a response time below 60 sec. and detection abilities as low as 200 ppb. While investigating the impact of rare-Earth cations, a predominant Ni 3+ –O–Mn 3+ interaction and acquisition of optimal e g 1 electron configuration of transition metal atoms in La 2 NiMnO 6 was found responsible for improved electrocatalytic and redox chemical activity that substantiates the sensing behavior. The study carefully scrutinizes the sensing mechanism to abide by the mixed-potential model. Moreover, the durability assessed over a month of operation supported the applicability of presented sensing elements in on-board NO X monitoring systems.

Integrity signals

Registry

Crossref · 10.1149/1945-7111/aca2e0

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These sensors achieved a sensitivity of 50 mV/decade, a response time of less than 60 s, a detection limit as low as 200 ppb, and durability for up to 1 month.

    “These sensors achieved a sensitivity of 50 mV/decade, a response time of less than 60 s, a detection limit as low as 200 ppb, and durability for up to 1 month.”
  • Bhardwaj et al. developed electrodes using double-doped Dy0.8W0.4Bi0.88O1.5-δ and Ln2NiMnO6, enabling operation within the 325°C-500°C range.

    “Bhardwaj et al. [154] developed electrodes using double-doped Dy 0.8 W 0.4 Bi 0.88 O 1.5-δ and Ln 2 NiMnO 6 , enabling operation within the 325°C-500°C range (Figure 10B).”

Cites

Flagged first, then by citations

1 of the 48 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Bhardwaj, A., Bae, H., Mathur, L., Mathur, S., & Song, S.-J.
Affiliations
University of Cologne (DE)
Venue
Journal of The Electrochemical Society
Published
2022-11-01
Volume
169
Issue
11
Pages
117510
ISSN
  • 0013-4651 (ISSN-L)
  • 1945-7111
OpenAlex
W4309224171
Cited by
7
References
48
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 2
FWCI
0.34
Type
journal article
Language
en
Open access
closed
Locations
Journal of The Electrochemical Society (publishedVersion)
Funders
National Research Foundation of Korea (2018R1A5A1025224)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Materials Science › Materials Chemistry › Catalytic Processes in Materials Science
Keywords
nitric oxide detection, bismuth oxide, double perovskite oxides, rare earth cations, electrocatalytic activity, mixed potential model, high-temperature sensing, sensor durability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review