CoChat

Strain Derivatives for Practical Charge Rate Characterization of Lithium Ion Electrodes

Open access
Schiffer, Zachary J., Cannarella, John, Arnold, Craig B. · 2016 · Journal of The Electrochemical Society

The DOI matches its Crossref record; 22 of the 23 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

During battery use, electrode materials are known to expand and contract in repeatable patterns, and this strain has been previously correlated with battery properties such as state of charge and state of health. In this study, we show that the second derivative of strain, d 2 ɛ/dQ 2 , is mathematically proportional to dV/dQ within an electrode stage. We also experimentally quantify peaks in the strain curves for electrode stage transitions at practical charge rates of up to C/2 and confirm that transitions are visible in the practical scenario of discharging at the higher rate of 1C. Moreover, the location of the transition measured by d 2 ɛ/dQ 2 changes by less than 10% from 0.05 C to 0.5 C, but the transition measured with dV/dQ decreases by more than 15% from 0.05 C to 0.3 C, demonstrating the reliability of strain to measure electrode transitions at moderate charge rates. We also note that d 2 ɛ/dQ 2 exhibits similar peak shifts as those expected in dV/dQ as the cell ages. Our derivations for the model system of graphite and lithium cobalt oxide can be generalized to other battery systems and used to characterize materials at practical charge rates impossible with only voltage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/2.0091603jes

Cites

22 of 23 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
Image 2
CC-BY · From the PDF
Image 3
CC-BY · From the PDF
Figure 1 Aschematic of the dilatometer used in this experiment. The battery is placed under an LVDT sensor to measure expansion and the entire setup is kept at 35 ◦ C.
Figure 1 Aschematic of the dilatometer used in this experiment. The battery is placed under an LVDT sensor to measure expansion and the entire setup is kept at 35 ◦ C.CC-BY · From the PDF
Figure 2 Strain ( ε ) from a single charge cycle (a), direct comparison of d ε /dQ and dV/dQ (b), and d 2 ε /dQ 2 and dV/dQ (c) for a commercial battery cycling at C/20. Select transitions are labeled and the similarity between the d 2 ε /dQ 2 and dV/dQ peaks is visually apparent.
Figure 2 Strain ( ε ) from a single charge cycle (a), direct comparison of d ε /dQ and dV/dQ (b), and d 2 ε /dQ 2 and dV/dQ (c) for a commercial battery cycling at C/20. Select transitions are labeled and the similarity between the d 2 ε /dQ 2 and dV/dQ peaks is visually apparent.CC-BY · From the PDF
Figure 3 Comparison of d ε /dQ (a), d 2 ε /dQ 2 (b), and dV/dQ (c) at charge rates up to C/2.. Dashed lines in (b) and (c) indicate transition movement as charge rate changes. Note the vanishing peak as charge rate increases in the voltage data (c) while a distinct curvature remains present in the strain data (b).
Figure 3 Comparison of d ε /dQ (a), d 2 ε /dQ 2 (b), and dV/dQ (c) at charge rates up to C/2.. Dashed lines in (b) and (c) indicate transition movement as charge rate changes. Note the vanishing peak as charge rate increases in the voltage data (c) while a distinct curvature remains present in the strain data (b).CC-BY · From the PDF
Figure 4 Comparison of dV/dQ (a) and d 2 ε /dQ 2 (b) in the practical scenario of discharging at 1 C. There are no visible peaks in the voltage data but there are definite peaks at the major transitions in the strain data. The black line in the (b) marks the 0 point, and the transitions are labeled in (b).
Figure 4 Comparison of dV/dQ (a) and d 2 ε /dQ 2 (b) in the practical scenario of discharging at 1 C. There are no visible peaks in the voltage data but there are definite peaks at the major transitions in the strain data. The black line in the (b) marks the 0 point, and the transitions are labeled in (b).CC-BY · From the PDF
Figure 5 Gaussian parameters for transition 1. The height of transition (a) and the position of the transition (b). The heights of the transition are in arbitrary units. Error bars represent 95% confidence on fit parameters. Note that the strain transition remains visible up to C/2 whereas the voltage transition does not. The voltage transition also shifts with charge rate significantly more than the strain transition.
Figure 5 Gaussian parameters for transition 1. The height of transition (a) and the position of the transition (b). The heights of the transition are in arbitrary units. Error bars represent 95% confidence on fit parameters. Note that the strain transition remains visible up to C/2 whereas the voltage transition does not. The voltage transition also shifts with charge rate significantly more than the strain transition.CC-BY · From the PDF
Figure 6 Comparison of d 2 ε /dQ 2 between cycle number 1 and cycle 50. Cycle 50 is offset vertically (zero point marked by dashed horizontal line), and the major transitions are labeled. The large noise at very high states of charge is due to imprecision in the numerical second derivative at the edge. The shift in the peaks due to aging is visible, similar to shifts expected in the voltage data.
Figure 6 Comparison of d 2 ε /dQ 2 between cycle number 1 and cycle 50. Cycle 50 is offset vertically (zero point marked by dashed horizontal line), and the major transitions are labeled. The large noise at very high states of charge is due to imprecision in the numerical second derivative at the edge. The shift in the peaks due to aging is visible, similar to shifts expected in the voltage data.CC-BY · From the PDF
Figure 7 A schematic of derivatives to clarify derivation of relationship between d 2 ε /dQ 2 and dV/dQ. The top three schematics are expansion (strain) derivatives (red) and the bottom two graphs are voltage derivatives (blue). Arrows indicate a derivative transformation between curves. The two transitions are schematically similar to a graphite system.
Figure 7 A schematic of derivatives to clarify derivation of relationship between d 2 ε /dQ 2 and dV/dQ. The top three schematics are expansion (strain) derivatives (red) and the bottom two graphs are voltage derivatives (blue). Arrows indicate a derivative transformation between curves. The two transitions are schematically similar to a graphite system.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Schiffer, Z. J., Cannarella, J., & Arnold, C. B.
Affiliations
  • Princeton University (US)
  • DuPont (United States) (US)
Venue
Journal of The Electrochemical Society
Published
2015-12-16
Volume
163
Issue
3
Pages
A427-A433
ISSN
  • 0013-4651 (ISSN-L)
  • 1945-7111
OpenAlex
W2562129302
Cited by
59
References
22
Citations by year
2026: 4 · 2025: 6 · 2024: 6 · 2023: 6 · 2022: 4 · 2021: 9 · 2020: 6 · 2019: 4 · 2018: 3 · 2017: 4 · 2016: 7
FWCI
4.81
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
Journal of The Electrochemical Society (publishedVersion, cc-by)
Topics
  • Physical Sciences › Engineering › Automotive Engineering › Battery Modeling and Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Battery Materials
  • Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
Keywords
lithium-ion batteries, strain derivatives, charging rate, graphite, LiCoO2, battery state of health, battery degradation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.