The DOI matches its Crossref record.
Electrolyzer Durability at Low Catalyst Loading and with Dynamic Operation
Open accessAbstract
Membrane electrode assembly durability is explored for polymer electrolyte membrane electrolyzers, focusing on catalyst (iridium, Ir) degradation at low loading and dynamic operation. Low catalyst loading and high cell potential are critical to observing durability losses over reasonably short experiments, regardless of test profile. While small losses are seen during steady operation, cycling greatly accelerates performance decreases. Ir dissolution mechanistically drives performance loss, thinning the anode catalyst layer and resulting in increasing kinetic losses during extended operation. While morphological changes to the catalyst layer are found, increasing polarization resistance suggests that degradation at the catalyst/ionomer/membrane interface may also contribute. Electrolyzer operation with model wind and solar profiles results in less severe performance losses compared to triangle- and square-wave potential cycling due to the lower cycling frequency of the renewable profiles. However, in both cases kinetics dominated the loss, indicating that higher cycling rates accelerate loss and can be used to project the impact of intermittency on device lifetime. These results suggest that performance losses impact electrolyzers' abilities to operate with low catalyst loading and intermittent inputs, and that a combination of component development and system controls are needed to limit potential and performance loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Is iridium demand a potential bottleneck in the realization of large-scale PEM water electrolysis?
Minke, C., Suermann, M., Bensmann, B., & Hanke-Rauschenbach, R. (2021) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2021.04.174 · Cited by 478
Decarbonization of the chemical industry through electrification: Barriers and opportunities
Mallapragada, D. S., Dvorkin, Y., Modestino, M. A., Esposito, D. V., Smith, W. A., Hodge, B.-M., Harold, M. P., Donnelly, V. M., Nuz, A., Bloomquist, C., et al. (2023) · Joule · doi:10.1016/j.joule.2022.12.008 · Cited by 359
Roll-to-roll production of catalyst coated membranes for low-temperature electrolyzers
Park, J., Kang, Z., Bender, G., Ulsh, M., & Mauger, S. A. (2020) · Journal of Power Sources · doi:10.1016/j.jpowsour.2020.228819 · Cited by 115
Phan, T. T., Kim, S.-K., Islam, J., Kim, M.-J., & Lee, J.-H. (2024) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2023.09.274 · Cited by 66
Metadata
- Authors
- Alia, S. M., Stariha, S., & Borup, R. L.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2019
- Volume
- 166
- Issue
- 15
- Pages
- F1164-F1172
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2981428570
- Cited by
- 263
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrolyzer Durability at Low Catalyst Loading and with Dynamic Operation. https://app.cochat.ai/papers/10.1149/2.0231915jes
- The paper
- Alia, S. M., Stariha, S., & Borup, R. L. (2019). Electrolyzer Durability at Low Catalyst Loading and with Dynamic Operation. Journal of The Electrochemical Society. https://doi.org/10.1149/2.0231915jes
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.