3D Printed Flow Field and Fixture for Visualization of Water Distribution in Fuel Cells by X-ray Computed Tomography
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This work demonstrates an original approach to three-dimensional, high-resolution, non-destructive visualization of fuel cells during room temperature operation using a commercial micro-X-ray computed tomography (XCT) system. The novel application of 3D printing technology was used to create a customized housing fixture that allows for non-invasive imaging of an operational fuel cell. The use of 3D print materials also allows for rapid prototyping and intricate design of any experimental fixture with minimal cost. Demonstration of imaging capabilities is shown through in situ visualization of the internal MEA components and liquid water after fuel cell operation. Water imaging in fuel cells is particularly challenging using XCT due to small differences in X-ray absorption characteristics between constituent materials. Image processing operations are discussed which allows for the improved segmentation of solid and water to calculate porosity and saturation throughout the gas diffusion layer, as reported herein. Additionally, a membrane thickness increase of approximately 25% due to swelling under 100% relative humidity is shown, which has previously been difficult to determine. Overall, the results shown here illustrate the novel use of 3D printed materials and image processing steps to be further used in understanding of fuel cell devices through non-invasive imaging procedures by use in a commercial micro-XCT system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, J., Yip, R., Antonacci, P., Ge, N., Kotaka, T., Tabuchi, Y., & Bazylak, A. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0221507jes · Cited by 112
Water sorption and expansion of an ionomer membrane constrained by fuel cell electrodes
Goulet, M.-A., Arbour, S., Lauritzen, M., & Kjeang, E. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.10.040 · Cited by 40
Self-citation
Cited by
Operando characterization techniques for electrocatalysis
Li, J., & Gong, J. (2020) · Energy & Environmental Science · doi:10.1039/d0ee01706j · Cited by 290
A lung-inspired approach to scalable and robust fuel cell design
Trogadas, P., Cho, J. I. S., Neville, T. P., Marquis, J., Wu, B., Brett, D. J. L., & Coppens, M.-O. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02161e · Cited by 210
Singh, Y., White, R. T., Najm, M., Haddow, T., Pan, V., Orfino, F. P., Dutta, M., & Kjeang, E. (2019) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.11.049 · Cited by 118
Self-citationWhite, R. T., Wu, A., Najm, M., Orfino, F. P., Dutta, M., & Kjeang, E. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.03.058 · Cited by 109
Self-citationChen, Y., Singh, Y., Ramani, D., Orfino, F. P., Dutta, M., & Kjeang, E. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.230674 · Cited by 30
Self-citation
Metadata
- Authors
- White, R. T., Orfino, F. P., Hannach, M. E., Luo, O., Dutta, M., Young, A. P., & Kjeang, E.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2016
- Volume
- 163
- Issue
- 13
- Pages
- F1337-F1343
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2519424959
- Cited by
- 56
- References
- 2
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.