The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Na-Ion Desalination (NID) Enabled by Na-Blocking Membranes and Symmetric Na-Intercalation: Porous-Electrode Modeling
Open accessAbstract
A new device concept, Na-Ion Desalination (NID), is introduced to desalinate NaCl from water using Na-ion battery (NIB) intercalants. A two-dimensional porous-electrode model is used to predict the performance of NID cells operating at sea- and brackish-water salinity-levels by simulating electrolyte transport, membrane polarization, and simultaneous electrochemistry. Anion-selective membranes are used to isolate electrodes in NID cells because simulations showed substantial drop from influent salinity (63%) compared to porous separators used in conventional NIBs (22%). Symmetric NIB intercalants and energy recovery were used to minimize energy consumption. A Na 0.44 MnO 2 -based NID-cell with 0.5 mm-thick electrodes desalinated 700 mM influent by 63% while consuming only 50% more energy (0.74 kWh/m 3 ) than thermodynamic minimum when cycled at C/2 rate. The high volumetric charge-capacity of NIB intercalants enabled 59–64% drop in influent salinity with water-recovery levels up to 80% and 95% for 700 mM and 70 mM influent, respectively. The present predictions of NID performance are optimistic (side reactions, intercalant decomposition, membrane leakage, and competing cation-intercalation are neglected), providing mechanistic insights into NID operation that will guide NID development in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling of Galvanostatic Charge and Discharge of the Lithium/Polymer/Insertion Cell
Doyle, M., Fuller, T. F., & Newman, J. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2221597 · Cited by 4,328
Simulation and Optimization of the Dual Lithium Ion Insertion Cell
Fuller, T. F., Doyle, M., & Newman, J. (1994) · Journal of The Electrochemical Society · doi:10.1149/1.2054684 · Cited by 2,057
Cited by
Hong Ng, V. M., Huang, H., Zhou, K., Lee, P. S., Que, W., Xu, J. Z., & Kong, L. B. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta06772g · Cited by 784
Srimuk, P., Su, X., Yoon, J., Aurbach, D., & Presser, V. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0193-1 · Cited by 665
Electrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
MXene as a novel intercalation-type pseudocapacitive cathode and anode for capacitive deionization
Srimuk, P., Kaasik, F., Krüner, B., Tolosa, A., Fleischmann, S., Jäckel, N., Tekeli, M. C., Aslan, M., Suss, M. E., & Presser, V. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta07833h · Cited by 482
Various cell architectures of capacitive deionization: Recent advances and future trends
Tang, W., Liang, J., He, D., Gong, J., Tang, L., Liu, Z., Wang, D., & Zeng, G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.064 · Cited by 461
Metadata
- Authors
- Smith, K. C., & Dmello, R.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2016
- Volume
- 163
- Issue
- 3
- Pages
- A530-A539
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2280518779
- Cited by
- 180
- References
- 2
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.